G45
Technical data - Transport and unpacking
In case of two- and three-chamber ovens, each oven
shall be connected with a special knife switch, it is
not possible to connect more than one oven to one
knife switch.
3.3.b - Unipotential connection (Fig 5)
The equipment shall be inserted in a unipotential system,
whose effectiveness shall be veri ed according to the
rules being in force.
A cascade connection shall be carried out among the
various oven components by using the screw (1) placed
on the rear oven side.
3.4 - OVEN POSITIONING (Fig 6)
The oven SHALL NOT BE INSTALLED against  am-
mable walls such as furniture, partitioning walls,
matchboarding coatings, etc.... We recommend
to keep a safety distance of at least 20 cm from
the back of the oven. The pavement of the area in
which the oven is installed shall not be made of
 ammable material.
• Position the oven on its  nal installation area following
the indications given in  gure 6, since they indicate
the minimum necessary distances as to have the oven
correctly functioning.
• Block the position of the oven applying the brakes
on the castors (optional) that are positioned on the
controls side.

3.5 - FIRST STARTING

At the end of the installation and before turning the
oven on, carefully clean its internal part as indica-
ted in "Maintenance" chapter, checking for the pre-
sence any possible foreign or  ammable body.
• Turn the oven on as indicated in "Running" paragraph,
verifying that it correctly reaches the established tem-
perature and that the different options are running.
DANGER
DANGER
DANGER
1
FIG. 6
200 mm
1000 mm
FIG. 5
EN - 13