UL Markings
Use 60°C or 75°C copper wire only for every model of this section.
}
Tightening torque and wire size for field wiring terminals.
}
–
–
For use in a pollution degree 2 environment only.
}
These devices provide solid state motor overload protection at 130% of full load cu-
}
rrent.
Integral solid state short circuit protection does not provide branch circuit protection.
}
Branch circuit protection must be provided in accordance with the National Electrical
Code and any additional local codes.
These devices are not provided with motor over-temperature sensing.
}
Suitable for use on a circuit capable of delivering not more than 42kA rms symmetrical
}
amperes" for a max. Voltage of 480 Vac.
Supply circuit protection:
}
Model
PMCprotego D.48
PMCprotego D.72
For use on a solidly grounded wye source only.
}
3.1.5
Función de seguridad STO
La función de seguridad "Par con desconexión segura" (Safe Torque Off, STO) activa el
bloqueo de impulsos del servoamplificador e interrumpe la alimentación del motor. Cumple
los requisitos según EN 61800-5-2.
Las entradas STO1-ENABLE y STO2-ENABLE corresponden, en
control monocanal sin realimentación, a los requisitos según EN ISO 13849-1: PL d
}
(cat. 2) y EN/IEC 62061: SIL CL 2.
control bicanal con realimentación, a los requisitos según EN ISO 13849-1: PL e (cat.
}
4) y EN/IEC 62061: SIL CL 3.
Para activar la función de seguridad STO, puede utilizarse también la tarjeta de seguridad
PMCprotego S1 o PMCprotego S2.
Manual de instrucciones PMCprotego D.48, PMCprotego D.72
1001735-ES-04
X0 8-2 AWG, TQ Lb In. 40.
X8 8-2 AWG, TQ Lb In. 40.
Fuse class
RK5, CC, J, T
RK5, CC, J, T
IMPORTANTE
Con activación bicanal de las entradas STO1-ENABLE y STO2-ENABLE,
es preciso comprobar periódicamente la conmutación segura del bloqueo
de impulsos. Véase al respecto el apartado 4.3.3 "Función de seguridad
STO".
Voltage Rating
600 VAC
600 VAC
Max. Fuse and SCC Ra-
ting
60 A / 200 kA
80 A / 200 kA