12 STARTING UP AFTER LONGER PERIODS OF INACTIVITY
▪
Remove the sparking plug.
▪
Quickly pull the starter cord right through several times in order to remove oil and deposits
in the engine compartment.
▪
Check the sparking plug, replace it if necessary and screw it in.
▪
Fill the petrol tank with the 2-stroke mixture.
13 TECHNICAL DATA
Engine displacement
Construction
Spark plug type
Fuel tank capacity
Blade length
Blade speed
Max. engine speed
Engine idle speed
Rotating rear handle
Max power
Engine oil / gasoline mixed ratio
14 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
Acoustic power level LwA
ATTENTION!
over 85 dB(A).
aw (Vibration)
15 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a special
connecting cable which is available from our service department. Replacement of the
connecting cable should only be carried out by our service department (see last page) or by
a qualified specialist (qualified electrician).
16 TROUBLE SHOOTING
PROBLEM
PROBABLE CAUSE
Unit won't
▪
▪
start or starts
but will not
▪
run.
▪
▪
Copyright © 2019 VARO
Wear
hearing
Incorrect starting procedures.
Incorrect carburettor mixture
adjustment setting.
Fouled sparking plug.
Empty fuel tank.
Primer bulb was not pressed
enough.
P a g e
POWPG30110
22.2cc
Hand-held
Champion
440ml
610mm
4.000r/min
10.000r/min
3.100r/min
Yes
0.68Kw
1:40
95 dB(A)
107 dB(A)
protection
when
3 m/s²
CORRECTIVE ACTION
▪
Follow instructions in the User
Manual.
▪
Have carburettor adjusted by an
Authorized Service Centre.
▪
Clean/gap or replace plug.
▪
Fill fuel tank with properly mixed
fuel.
▪
Press primer bulb fully and slowly
10 times.
| 14
sound
pressure
K = 1,5 m/s²
www.varo.com
EN
is