Air cleaner
Important: a clogged air cleaner reduces engine performance. Operating with no element
or
with a bent or damaged element causes irregular wear and tear of the engine mechanism.
9.4
Air cooling
This engine is air-cooled. Dust clogging up the air cooling inlet port and the cylinder fins will
cause the engine to overheat. Periodically check and clean the cylinder fins after removing
the air cleaner and the cylinder cover.
9.5
Anti-vibration system
Copyright © 2019 VARO
POWPG30110
Release the air cleaner cover and
remove the
dust.
If the element is dirty, clean it by
tapping it, by
blowing away the dirt or clean in
warm, soapy water (dry
completely before installing).
If the element is bent or
damaged, replace it.
After you have cleaned the
element reattach it to
the cleaner body with the stamp
on the outside
(facing the cleaner cover).
After that, replace the cleaner
cover.
The deformed or damaged anti-vibration
system may cause of the breakages like getting
rickety or falling off of engine and/or blade .
Check periodically if the springs are not
deformed or damaged