Electronic Programmer - Cardin Elettronica SLX Serie Manual Del Usuario

Automatización para cancillas correderas con motor de corriente continua
Ocultar thumbs Ver también para SLX Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
horised copying or use of the information contained in this document is punishable by law
MANUAL MANOEUVRE WITH THE MOTOR RELEASED
Manual release is to be carried out with the motor Stopped. To release the gate use
the manual release key supplied with the unit. The key should be kept in an easily
accessible place.
SCREW OPERATED MANUAL RELEASE SYSTEM
A
5 - 6 turns
C
To release the unit (fig. 8)
Description :
Sblocco nuovo "A"
01
1. Lower the lock protection "A" on the release knob, insert the key "B" and rotate
SL1524SB
B
it through 180 degrees clockwise. The knob is now free and can be rotated.
:
13-11-2008
2. Rotate the knob "C" clockwise until reaches its travel limit. The geared motor is
Drawing number :
A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
now released and the gate can be moved manually.
Product Code :
Attention! Do not force the knob to exceed the travel limit.
Draft :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
To relock the unit (fig. 8)
Drawing number :
DM0804
Description :
Sblocco nuovo "C"
1. Rotate the knob "D" anticlockwise until it blocks completely.
Product Code :
SL1524SB
SL1524SB
Attention! Do not force the knob to exceed the travel limit.
Date :
Draft :
P.J.Heath
3-11-2008
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
2. Rotate the key anticlockwise and position the lock protection.
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
The geared motor is now locked and the gate may be used normally.
Once the system is running normally store the key in a safe place.
Attention! Never use the manual release mechanism while the gate
is in operation.
ghts reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Moving the gate manually will force the encoder to lose the position
of the gate. To reset the control, once the gate has been relocked,
you will need to give 3 or more movement commands so that the gate
leaf will reach the travel limit enough times to position itself correctly.
9
A
5 - 6 turns
D
Description :
DM0802
SL1524SB
SL1524SB
Date :
13-11-2008
Description :
Sblocco nuovo "D"
SL1524SB
13-11-2008
Access to the electronic card
Attention! Before opening the cover make
sure that the power has been switched off
at the mains.
To access the motor loosen the two
screws "A" positioned on either end of the
cover as indicated in figure 9.

ELECTRONIC PROGRAMMER

Electronic programmer for a dc motor with an incorporated radio receiver card, which
allows the memorisation of 300 user codes (see "remote control" page 20). The
"rolling code" type decoder uses 433.92 MHz series transmitters.
The motor rotation speed is electronically controlled, starting slowly and increasing
in speed; the speed is reduced as it nears the travel limit so as to enable a controlled
smooth stop.
Programming is carried out using one button and allows you to set the system, the
8
current sensor and the entire gate travel distance while the logic carries out position
control using an encoder.
The intervention of the anticrush/antidrag sensor during the closing and opening
stages causes a brief (10 cm) travel direction inversion then a block.
180°
B
• After having installed the device, and before powering up the program-
• The controlled load output (binding post 15) is aimed at reducing battery
• When a command is received, via radio or via wire, the electronic program-
All rights reserved. Unauthorised copying or use of the information contained in
• Connecting devices to the controlled output contact also allows you to
Sblocco nuovo "B"
• The presence of the electrical current sensor does not dispense with the
• Before connecting the appliance make sure that the voltage and frequency
• For the 230 Vac power supply only use a 2 x 1.5 mm
• The cable may only be replaced by qualified technicians.
• An all pole trip switch with at least 3 mm between the contacts must be
• Don't use cables with aluminium conductors; don't solder the ends of
• The terminal wires must be positioned in such a way that both the wire
Mains power supply connection
• Connect the control and security device wires.
• Run the mains power supply through the cable clamp located on the bottom right
of the main circuit board and to the separate 3-way terminal board:
- connect the neutral to binding post N
- connect the earth to binding post
- connect the live to binding post L
16
IMPORTANT REMARKS
Attention! There is no 230 Vac contact on any part of the electronic card:
only low voltage safety current is available.
In conformity with the electrical safety standards it is forbidden to connect
binding posts 9 and 10 directly to a circuit that receives power greater
than 30 Vac/dc.
Warning! For the correct operation of the programmer the incorporated
batteries must be in good condition: the programmer will lose the posi-
tion of the gate in case of blackouts when the batteries are flat the alarm
will sound.
Check the good working order of the batteries every six months (see page
19 "Battery check").
mer, release the door (manual release mechanism) and move it manually,
checking that it moves smoothly and has no unusual points of resistance.
power consumption (if installed) during blackouts; photocells and other
safety devices should be connected to this output.
mer routes voltage to the CTRL 24 Vdc output. It then evaluates the state
of the safety devices and if they are at rest it will activate the motor.
carry out the autotest function (enabled using "TEST FI" and "TEST FS" in
the "OPTIONS" menu) and check that the safety devices are functioning
correctly.
obligation to install photoelectric cells and other safety devices foreseen
by the safety standards in force.
rated on the data plate conform to those of the mains supply.
installed between the unit and the mains supply.
cables which are to be inserted into the binding posts; use cables marked
T min 85°C and resistant to atmospheric agents.
and the insulating sheath are tightly fastened (a plastic jubilee clip is suf-
ficient).
2
+
cable.
N
L
Tabla de contenido
loading

Este manual también es adecuado para:

Slx1524

Tabla de contenido