DeWalt DCM565N Traducción De Las Instrucciones Originales página 52

Ocultar thumbs Ver también para DCM565N:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
EnGLIsh
TROUBLESHOOTING
Problem
Solution
Unit will not start.
Check battery installation.
Check battery
charging requirements.
Check that lock off is fully pushed
down prior to moving main trigger.
Unit shuts down
Charge battery.
in use.
Unit is being forced. Restart and
apply less pressure.
Battery
Insert battery into charger until red
won't charge.
charging light illuminates. Charge up
to 8 hours if battery is totally drained.
Plug charger into a working outlet.
Refer to Important Charging Notes
for more details.
Check current at receptacle by
plugging an appliance.
Check to see if receptacle is
connected to a light switch which
turns power off when you turn out
the lights.
Move charger and appliance to
a surrounding air temperature of
above 4.5 °C or below 40.5 °C.
Bar /
Refer to Adjusting Chain
Chain overheated.
Tension section.
Refer to Chain Oiling section.
Chain is loose.
Refer to Adjusting Chain
Tension section.
Refer to Adjusting Chain
Poor cut quality.
Tension section. nOTE: Excessive
tension leads to excessive wear and
reduction in life of bar and chain.
Lubricate before each cut. Refer to
Replacing the Saw Chain section.
Unit runs but does
Chain could be installed backwards.
not cut.
Refer to sections for installing and
removing chain.
Unit does not oil.
Refill oil reservoir.
Clean guide bar, sprocket and
sprocket cover. Refer to Care And
Maintenance section.
50
loading

Este manual también es adecuado para:

Dcm565n-xj