• Press and hold "PROG" button for 3 sec. to enter into basic menu. The
indicator light L0 will flicker once, then L1 will be steady on.
• Press "PROG" button again for 3 sec. to enter into advanced menu. L0 will
flicker twice, then L1 will be steady on.
• Press "PROG" button for 3 sec. for the third time to enter into other menu
setting. L0 will flicker three times, then L1 will be steady on.
• Press "SET" button once to enter into emergency stop distance setting. The
Indicator light L1 to L5 will show the current setting value. (Default is L2).
• Press "+" or "-" button to set the emergency stop distance. The indicator lights
L1-L5 will indicate different distance, the more the indicator lights are on, the
longer the distance will be, the better the buffering will be before gate
stopped.
• Press "SET" button once to save and system will automatically exit. The
indicator lights L1-L5 will be on in sequence, then all will flicker once and off.
BUZZER SETTING (L2)
This setting is to enable or disable the buzzer, users can set to their required.
There are four types of buzzer this motor will make for different conditions:
• Motor works normally under mains power: the buzzer sounds short but long
lasting.
• Motor works normally under battery power: the buzzer sounds strident but
long lasting, and will stop after 6 sec.
• Motor works abnormal due to low battery power: the buzzer sounds strident
but long lasting, and will stop after 3 sec.
• Motor works abnormal due to control board error: the buzzer sounds strident
but long lasting.
Operation instruction: