OPENING DIRECTION SETTING (L4)
This setting is for users to change the gate opening direction without exchanging
the motor wires, but have to note the limit stop position.
Operation instruction:
• Press and hold "PROG" button for 3 sec. to enter into basic menu. The
indicator light L0 will flicker once, then L1 will be steady on.
• Press "PROG" button again for 3 sec. to enter into advanced menu. L0 will
flicker twice, then L1 will be steady on.
• Press "+" button three times to select opening direction option. The indicator
light L4 will be steady on.
• Press "SET" button once to enter into opening direction setting. The indicator
light L1 will indicate the current setting. (Default is L1 on).
• Press "+" or "-" button to set the opening direction. The indicator light L1 on or
off stands for the 2 directions. (L1 on: open to right-hand; L1 off: open to left-
hand) Press "SET" button once to save and system will automatically exit. The
EN
- Flicker
Cancel
start-up
delay function
Delay for 0.5 sec.
Delay for 1 sec.
Delay for 1.5 sec.