B. Three Button Mode (L2)
Terminals for external buttons:
OSC – opening button
PED – closing button
STP – stop button
C. Community Mode (L3)
Terminals for external buttons:
OSC – single button control
PED – pedestrian button
STP – stop button
Special function - only when the gate is completely open, can be closed thereafter.
If the gate is not completely open, then only opening and stop can be operated in
order to prevent any interruption which will trigger closing during the opening
travel operated by the first user.
Operation instruction:
• Press and hold "PROG" button for 3 sec. to enter into basic menu. The
indicator light L0 will flicker once, then L1 will be steady on.
• Press "PROG" button again for 3 sec. to enter into advanced menu. The
indicator light L0 will flicker twice, then L1 will be steady on.
• Press "SET" button once to enter into working mode setting. The indicator
lights L1-L3 will show the current selection. (The default is L1).
• Press "+" or "-" button to select the working mode. The indicator lights L1-L3
will show the current selection.