07 - EXAMPLE CONNECTION WITH WEGO RFID READER
WeGo RFID Reader
1 2 3 4 5 6 7 8 9
Exclusive
power supply
of the lock
NA
Lock
24
Check whether the lock or electromag-
NF
net being used works with NC or NO
contacts and select the WeGo Exit But-
ton wire according to this specification.
NOTES: The connection to the WeGo
Exit Button is via RS485 and the commu-
nication is via the Nice proprietary proto-
col. The baud rate is 9600 bps (bits per
second) and it is recommended to use
cables with a distance of less than 1000
meters.
Power Source
12VDC / 1A
-
+
ENGLISH
WeGo Exit Button
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16