OPERATING AND MAINTENANCE MANUAL
VERTICAL ELECTRIC PUMP VERTI SERIES
6. PROBLEM SOLVING
PROBLEM
The pump does not rotate.
It does not pump properly.
7. TRANSPORT
The machines in question shall be supplied in suitable packaging to ensure proper protection
during all stages of transport. If, on receipt of the goods, the packaging is damaged, it is
necessary to ensure that the machine has not been damaged during transport and that it has
not been tampered with. In the event of damage to the equipment or if any part of the machine
is found to be missing, the transporter and the manufacturer must be notified immediately
and the corresponding photographic documentation must be provided. Materials used to
protect the equipment during transport must be disposed of using the disposal channels
existing in the country of destination.
8. LIFTING AND DISPLACEMENT
For all lifting and moving operations, the operator must use the minimum personal protection
devices required for the operations to be carried out (safety footwear, gloves and protective
helmet).
www.proindecsa.com / [email protected]
POSSIBLE REASON
1. Insufficient power to the pump
1.Blockage or leakage
1. Low voltage
12
SOLUTION
1. Incoming power to the pump?
2. Is circuit breaker turned on?
3. GFCI working properly?
4. Is the air switch plugged in?
1. The jets should be pointed away from
the suction inlet so that air does not
enter the suction.
2. Is the suction inlet in the pool blocked
or covered?
3. Is there any debris in the pump
casing?
4. Is there a leak in the piping or pump?
1. Is the proper voltage applied to the
pump?
2. Is an extension cable being used?