Nozzle change operation
1. Please use driver with special head for removed and install nozzle as.
(figure 3)
2. Please remove nozzle (figure 4) from burner with special nozzle driver
and install new nozzle. (figure 5)
Figure 3
Ventilation of room
The air needed for burning is received from room air and the gases emit-
ted are given directly in room. For safe operation of your product, good
room ventilation is a precondition. If no window or room to be utilized
for room ventilation is available, additional ventilation should be installed.
However, room has a door opening outside, it is no needed to vent holes.
Room size
Smaller than 5 m³
Between 5 m³ - 10 m³
Bigger than 10 m³
In basement or cellar
Reduced gas flow rate setting for hob taps
1. Ignite the burner that is to be adjustment and turn the knob to the
reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust the flow rate adjust-
ment screw. For LPG (butane-pro pane) turn the screw clockwise. For
the naturel gas, you should turn the screw counter- clockwise once.
"The normal length of a straight flame in the reduced position should
be 6-7 mm."
4. If the flame is higher then the desired position, turn the screw clockwise.
If it is smaller turn anticolockwise.
5. For the last control, bring the burner both to higt-flame and reduced
positions and check whether the flame is on or off.
Figure 4
Ventilating opening
min. 100 cm²
Figure 5
min. 50 cm²
no need
min. 65 cm²