Electrical Connection
1. Your oven requires 16 or 32 Ampere fuse according to the appli-
ance's power. If necessary, installation by a qualified electrician is recom-
mended.
2. Your oven is adjusted in compliance with 220-240V AC/380-415V
AC 50/60Hz.electric supply. If the mains are different from this specified
value, contact your authorized service.
3. Electrical connection of the oven should only be made by the sock-
ets with earth system installed in compliance with the regulations. If
there is no proper socket with earth system in the place where the oven
will be placed, immediately contact a qualfied electrician. Manufacturer
shall never be responsible from the damages that will arise because
of the sockets connected to the appliance with no earth system. If the
ends of the electrical connection cable are open, according to the appli-
ance type, make a proper switch installed in the mains by which all ends
can be disconnected in case of connecting / disconnecting from / to the
mains.
4. If your electric supply cable gets defective, it should definitely be
replaced by the authorized service or qualfied electricians in order to
avoid from the dangers.
5. Electrical cable should not touch the hot parts of the appliance.
6. Please operate your oven in dry atmosphere.
Electrical connection scheme
380-415V 3N~50/60Hz
220-240V~50/60Hz
400V 3N~50/60Hz
220-240V~50/60Hz
L3
Neutral
Neutre
L2
Live
Earth
Phase
L1
Terre
Erdung
H05 VV-F 3G 4 mm²
H05 VV-F 5G 1.5 mm²
H05 VV -F 3G 4mm²
H05 VV -F 5G 1.5mm² H05 VV -F 4G 1.5mm²
380-415V 2N~50/60Hz
400V 2N~50/60H z
L2
Neutral
Neutral
Neutre
Neutre
Earth
Earth
L1
Terre
Terre
Erdung
Erdung
H05 VV-F 4G 1.5 mm²
220-240V~50/60Hz
220-240V~50/60H z
L1
Neutral
Neutre
Earth
Terre
Erdung
H05 VV-F 3G 1.5 mm²
H05 VV -F 3G 1.5m m²