THERMOSTAT FOR DUCTING SYSTEM

It's possible to check the on/off ventilation for the ducting system.
The equipment is supplied with second ventilation (Ventilazione2) to which is possible
connect a tubes to convey the hot air produced in the nearest rooms to the one of
installation.
In the back part of the equipment, it's present a
connector to which it's possible to connect a
thermostat/contact external to order the on/off
of Ventilation2.
Connect to the connector an auxiliary contact
(es.thermostat/timer) closing the contact, the
Ventilation2 will stop, when the contact is
open the Ventilation2 will function as program
selected in the Menu01.

CONTROL PANEL MENU

-Push on button P3 to have access to the menu
-Use buttons P5 and P6 to run on the different menu
-Push again on button P3 to enter into the displayed menu
-Use buttons P5 and P6 to run on the different submenu, the button P1 and P2 modify the
value shown on the display
-The button P3 accedes to the displayed menu/submenu
-The button P4 returns always to the previous menu
MENU
Menu 01 FAN REGULATION
Menu 02 SET WATCH (Setting the clock inside the equipment).
Menu 03 SET CHRONO (Set schedules for automatic on / off).
Menu 04 CHOSE LANGUAGE (Program the language of control panel).
Menu 05 STAND-BY (On/Off Stand-By)
Menu 06 SOUND (Setting the beep sound).
Menu 07 FIRST LOADING (On the loading pellet in continuous ).
Menu 08 STOVE STATUS ( To visual the equipment status).
Menu 09 CORRECT PELLETS (Correction of equipment carburation).
Menu 10 TECHNICAL CALIBRATIONS (Only for TECHNICAL STAFF).
This equipment is supplied by fans for entering of hot air into the rooms :
n. 1 (automatically regulated and not to be excluded ) in the frontal part;
n. 2 into the ducting system.
MENU 01 (fan regulation)
This menu set the function modalità of ducting system. Set the modality of functioning of
Ventilation2 and Ventilation3 ( if the equipment is supplied with ). Use the button 1 to modify
the ventilation2, use the button 2 to modify the ventilation3 ( if the equipment is supplied
with). The other possible functions are :
A – The set up ventilation will adapt automatically to equipment power.
0 – The setting ventilation will remain off.
1---5 – The ventilation selected will function always to selected power.
On display appears also the Ventilation3 : this is not to take into consideration because
it's not present and it's not available for this model.
49/124
IT IT IT IT- - - - GB
GB- - - - FR
FR- - - - E E E E S S S S mod. 531 – 531N
GB
GB
FR
FR
Open contact
Ventilation2 ON FUNCTION
Closed contact
Ventilation2 ON STOP
Tabla de contenido
loading

Este manual también es adecuado para:

Alicya 531n

Tabla de contenido