THERMOSTAT FOR DUCTING SYSTEM
It's possible to check the on/off ventilation for the ducting system.
The equipment is supplied with second ventilation (Ventilazione2) to which is possible
connect a tubes to convey the hot air produced in the nearest rooms to the one of
installation.
In the back part of the equipment, it's present a
connector to which it's possible to connect a
thermostat/contact external to order the on/off
of Ventilation2.
Connect to the connector an auxiliary contact
(es.thermostat/timer) closing the contact, the
Ventilation2 will stop, when the contact is
open the Ventilation2 will function as program
selected in the Menu01.
CONTROL PANEL MENU
-Push on button P3 to have access to the menu
-Use buttons P5 and P6 to run on the different menu
-Push again on button P3 to enter into the displayed menu
-Use buttons P5 and P6 to run on the different submenu, the button P1 and P2 modify the
value shown on the display
-The button P3 accedes to the displayed menu/submenu
-The button P4 returns always to the previous menu
MENU
Menu 01 FAN REGULATION
•
Menu 02 SET WATCH (Setting the clock inside the equipment).
•
Menu 03 SET CHRONO (Set schedules for automatic on / off).
•
Menu 04 CHOSE LANGUAGE (Program the language of control panel).
•
Menu 05 STAND-BY (On/Off Stand-By)
•
Menu 06 SOUND (Setting the beep sound).
•
Menu 07 FIRST LOADING (On the loading pellet in continuous ).
•
Menu 08 STOVE STATUS ( To visual the equipment status).
•
Menu 09 CORRECT PELLETS (Correction of equipment carburation).
•
Menu 10 TECHNICAL CALIBRATIONS (Only for TECHNICAL STAFF).
•
This equipment is supplied by fans for entering of hot air into the rooms :
n. 1 (automatically regulated and not to be excluded ) in the frontal part;
•
n. 2 into the ducting system.
•
MENU 01 (fan regulation)
This menu set the function modalità of ducting system. Set the modality of functioning of
Ventilation2 and Ventilation3 ( if the equipment is supplied with ). Use the button 1 to modify
the ventilation2, use the button 2 to modify the ventilation3 ( if the equipment is supplied
with). The other possible functions are :
A – The set up ventilation will adapt automatically to equipment power.
0 – The setting ventilation will remain off.
1---5 – The ventilation selected will function always to selected power.
On display appears also the Ventilation3 : this is not to take into consideration because
it's not present and it's not available for this model.
49/124
IT IT IT IT- - - - GB
GB- - - - FR
FR- - - - E E E E S S S S mod. 531 – 531N
GB
GB
FR
FR
Open contact
Ventilation2 ON FUNCTION
Closed contact
Ventilation2 ON STOP