Automatic Safety Features; Residual Risks - Lincar Betty 531 Manual Del Usuario - Mantenimiento

Equipos a combustible solido: pellets de madera
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Menu 09 PELLET CORRECT - (Correction of appliance combustion).
Display
ACCESS KEY
PELLET CHARGE
Menu 10 SETTINGS TECHNIC -(Reserved to TECHNICAL STAFF).
Display
TECHNICAL SETTINGS
ACCESS KEY
This section is reserved to the TECHNICIANS and permits to effect working regulations on the
SAFETY
Easy to use, safety of operation. The digital control panel order the combined action of
gas combustion fan, combustible loading, convection fan and checking of the room
temperature. This checking system grant the best combustion and functioning conditions,
reducing the costs of functioning.
Maximum efficiency, minimum emissions. The large heat exchange surface, together
with optimal control of combustion air, as a result provides an excellent yield of the fuel.
The release of the pellets dosed in the brazier, allows complete combustion with low
emissions in the exhaust gas.

AUTOMATIC SAFETY FEATURES

Voltage drop. Even after a brief power loss, the unit stops and then restarts, resuming the
normal operation or re-running the automatic ignition phase, without any security risk.
Shutdown due to overheating. In the event of abnormal heating appliance, the security
system that operates off the stove. The stove can then be turned back on after leaving it
to cool for at least 45 minutes. The persistence of this condition must be verified by the
service center or qualified personnel
Low-temperature shutdown. If the equipment temperature drops below a certain value,
the unit turns off (for example the end of the fuel). This can also be turned off when you
turn it too late. The stove must be turned back on. The persistence of this condition must
be verified by the service center or qualified personnel.
Electrical surge protection device. The appliance is protected against overcurrent by a
fuse (see technical data) placed: one on the electronic board and one on the power socket.
For its replacement, contact Technical Service

RESIDUAL RISKS

The stove does not present itself potential risks, although it is complete with coatings in all its
parts, nevertheless the following residual risks may be present:
Risk of burns
Between the back of the stove and the smoke outlet (fume outlet pipe).
Contact with glass
Electric risk
Alimentation cable ; Motors connection
Risk of fire
Opening the front door when the ashes are not extinguished.
Risk of cutting
Between the auger shaft and the material loading conduit; in the event of a jam, do not
carry out any material removal operations unless the stove has been switched off and the
power supply disconnected.
Description
Insert access key to accede to the combustion modification
Correction of combustible loading
Description
Menu reserved to TECHNICIANS
Insert access code