DUCTING SYSTEM
The equipment could be connected to a tube to convey the produced hot air in the adjacent rooms.
The exhaust ducting system is placed on back part of the stove so it's necessary to take into consideration that
it has not to be directed towards flammable material.
The ducting system air temperature can reach easily the 200°C, the ducting system tubes should be done by
fireproof material and the conduct must not come into direct contact with flammable material.
In case of crossing flammable walls, THE INSTALLATIONS MUST BE DULY SEALED on tubes that
cross over it, employing adequate seal material. The tubes inserted in the wall, must be insulated to not waste
warmth. It's necessary to safe animals and people from accidental contact with the tubes.
Read and respect in any case the laws in force. It's advisable to make a thermic insulation along all the tubes
installation to low the heat loss and to increase the caloric performance.
For ducting system to not overcome the 6 mt of lenght.
In case that the ducting system connection will be divided, it has to be the same length to
distribute uniformly the air, on the contrary the shortest duct will be privileged. In case of
double ducting system conduct, the total length ( the sum of both ducting ducts ) must not be
more than 6 mt.