SAFETY
Easy to use, safety of operation. The digital control panel controls the combined action of
the gas combustion fan, of the fuel loading, of the convection fan and of the control of the
room temperature. This control system grants the best combustion and functioning
conditions, reducing to the minimum the costs of functioning.
Maximum efficiency, minimum emissions. The large heat exchange surface, together
with an optimal control of the combustion air, provides an excellent yield of the fuel. The
release of the pellets dosed in the brazier, allows a complete combustion with low
emissions in the exhaust gas.
AUTOMATIC SAFETY FEATURES
Voltage drop. Even after a brief voltage drop, the unit stops and then restarts,
resuming the normal operation or restarting the automatic ignition phase, without
any security risk.
Shutdown due to overheating. In the event of abnormal heating of the appliance, the
security system intervenes and switch off the stove. The stove can then be switched on
again after leaving it to cool for at least 45 minutes. The persistence of this condition
must be verified by the service center or qualified personnel
Low-temperature shutdown. If the temperature of the appliance drops down to a certain
value, the unit turns off (for example the finishing of the fuel). This can also be switch off
can also accur if the lighting phase takes to much time. The stove must then be re switched
on again The persistence of this condition must be verified by the service center or
qualified personnel.
Electrical rotection device for overcurrent. The appliance is protected against
overcurrent by a fuse
its replacement, contact Technical Service
THERMOSTAT FOR THE CANALIZATION SYSTEM
It's possible to control the switch on/off of the ventilation for the canalization system.
The appliance is equipped with a second ventilation (Ventilation2) to which is possible to
connect a tube which conveys the hot air produced in an adjacent room.
On the back part of the appliance, there is a
connector to which it's possible to connect a
thermostat/external contact to control the
on/off of the Ventilation2.
Connect to the connector an auxiliary contact
(i,e,. a thermostat / timer) closing the contact,
the Ventilation2 will stop, when the contact is
open the Ventilation2 will function as set ted in
the Menu01.
(
see technical data) placed on the electronic card. For
51/124
IT-GB-FR-ES mod. 501-501X-501L-501LX
.
Open contact
Ventilation2 ON FUNCTION
Closed contact
Ventilation2 ON STOP