Limit Values (Numberer); Stamping A Constant Number - Reiner jetStamp 790 Manual De Instrucciones

Ocultar thumbs Ver también para jetStamp 790:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

jetStamp 790 / MP

2.5.6 Limit values (numberer)

Definition of the limit values that the numberer counts from and to,
e.g. starting at 10, stopping at 20 and starting again from 10.
Setting limit values
Press [MODE] until [COUNT] appears in the menu line.
Press [COUNT] until the required minimum value is set.
Press [MODE] until [N1 MIN] appears.
To save the minimum value, press [N1 MIN].
[N1 MIN] changes to [N1 MIN t].
Press [MODE] until [COUNT] appears.
Press [COUNT] until the required maximum value is set.
Press [MODE] until [N1 MAX] appears.
To save the maximum value, press [N1 MAX].
[N1 MAX] changes to [N1 MAX t].
The limit values are now set.
Deleting limit values
Press [MODE] until [N1 CLR] appears in the menu line.
To delete the set limit values, press [N1 CLR].

2.5.7 Stamping a constant number

You can also stamp using a number that doesn't change.
Imprint P: 08 to P: 10 must be chosen (see "Selecting imprint" on page 44).
Press [MODE] until [NO/TXT] appears in the menu line.
Press [NO/TXT].
"INPUT - PRE TEXT" appears.
Press [NEXT].
"INPUT - NUMBERER 1" appears.
Press [VARY].
To increase the number value, press [INC].
Press [DEC] to decrease the number value.
In order to move one digit to the right and modify this with [INC/DEC],
press [RIGHT].
Special characters can be set at each digit position.
To save changes and to return to the main menu,
press [RETURN] twice.
The main menu appears.
53
Tabla de contenido
loading

Este manual también es adecuado para:

Jetstamp 790 mp

Tabla de contenido