LABEL
MIN.
MAS.
u1
0
7
u2
0
1
u4
-
-
u5
-99
99
u6
1
120
u7
0
99
LABEL
MIN.
MAS.
HE2
0
999
HE3
0
240
LABEL
MIN.
MAS.
POF
0
1
PAS
-99
999
(1) the unit of measurement depends on P2
(2) properly set the parameters corresponding to the regulators after setting P2 parameter
(3) the temperature associated with regulation and the temperature alarms is the CPT temperature; the formula to calculate the CPT temperature is as follows: CPT
temperature ={[(parameter P7)x(inflowing air temperature)]+[(100-parameter P7)x(outflowing air temperature)]:100}
(4) if r5 parameter is set at 1, the "energy saving" function and the defrost management will be switched off; see also F1 parameter
(5) the parameter has effect even after an interruption in the power supply that occurs while the device is switched on
(6) the time set by paramenter C2 is counted also when the device is off ("stand-by" status)
(7) the differential of parameter is 2.0°C/4°F
(8) if when the device is switched on, the condenser temperature is already above that established in C7 parameter, then C8 parameter will not have effect
(9) the value Δt depends on r12 parameter (r0 if r12 = 0, r0/2 if r12 = 1)
(10) the display restores normal operation when, at the end of the dripping phase, room temperature or CPT temperature falls below the value that locked the display
(or if a temperature alarm is triggered)
(11) if P3 parameter is set at 0 or 2, the device will function as if d8 parameter were set at 0
(12) if when defrost is activated, the operating duration of the compressor is less than the time established with d15 parameter, the compressor will remain on for the
amount of time necessary to complete defrost, then the defrost shall be activated
(13) during defrost, dripping and evaporator fan standstill, the maximum temperature alarm is absent, provided that it was triggered after defrost activation.
(14) during activation of the door switch input, the maximum temperature alarm is absent, provided the alarm was signalled after the activation of the input
(15) F4 and F5 parameters have effect when the compressor is off
(16) F4 and F5 parameters have effect when the compressor is on
(17) if P3 parameter is set at 0, the device will function as if F0 parameter were set at 2
(18) F4 and F5 parameters have effect when the evaporator temperature is below the temperature established with F1 parameter
(19) F4 and F5 parameters have effect when the compressor is on and the temperature of the evaporator is below the temperature established with F1 parameter
(20) if the P4 parameter is set at 0, 2 or 3, the condenser fan shall work in parallel with the compressor
(21) the condenser fan is switched on provided that the compressor is switched on and is switched off when the condenser temperature falls below the value set with
parameter F11 provided that the compressor is switched off
(22) the compressor is switched off 10 s after the activation of the input; if the input is activated during defrost or when the evaporator fan is deactivated, the activation
will not have any effect on the compressor
(23) to avoid damaging the connected load, set the parameter when the device is switched off ("stand-by" status).
• Pas nu en niet eerder, kan men etenswaren in het apparat zetten.
• Leg de producten gelijkmating verspreid in de unit om de luchtcirculatie te
bevorderen.
• In de unit treft u stickers aan waar de laadlimiet van de roosters op staat vermeld.
• Leg de producten op het bovenste rooster slechts tot aan de stapelgrens.
• Geen producten onder het onderste schap.
• Laat de deur niet langer open staan dan nodig is om de levensmiddelen uit het
apparaat te pakken of in het apparaat te leggen.
OPGELET: Als het gaat over apparaten met interne verdamping
binnen de cel, en in het geval de omgevingsomstandigheden het
niet mogelijk maken dat het condensaatwater verwerkt wordt door
het
automatische
verdampingssysteem,
geïnstalleerd te worden op de achterwand van het apparaat, of moet het water naar het
waterafvoersysteem geleid worden.
U.M.
DIGITAL OUTPUTS
utility managed through the K4 digital output (23)
0 = ROOM LIGHTING - see parameters i0 and u2
1 = DEMISTER HEATING ELEMENTS - see parameter u6
2 = AUXILIARY OUTPUT - see parameters i5 and u2
-
3 = ALARM OUTPUT
4 = NEUTRAL AREA OPERATION HEATING ELEMENTS - see parameter u7
6 = CONDENSER FAN - see parameters P4, F11 and F12
7 = ON/STAND-BY OUTPUT - see parameter POF
room lighting switch on/off and auxiliary output enabling in manual mode when the device is switched
off ("stand-by" mode)
-
1 = YES
-
reserved
°C/°F (1)
room temperature or CPT temperature below which the door heating elements are switched on (7)
min
duration of demister heating elements operation
room temperature or CPT temperature below which the neutral area operation heating elements are
°C/°F (1)
switched on (with regard to the working setpoint, that is to say, "working setpoint + u7") (7)
U.M.
ENERGY SAVING
maximum duration of the "energy saving" function activated in manual mode due to the effect of
min
absence of door micro switch input activation; see also r4, F4, F5 and i10
0 = the function will last until the input is activated
time interval with no key strokes, after which the "low consumption" function is activated
min
0 = the mode shall never be aactivated
U.M.
VARIOUS
-
key activation
1 = YES
-
access password for the configuration parameters
0 = the password need not be set
INLEGGEN VAN PRODUCTEN
dan
dient
een
klein
opvangbekken
22