To select a parameter:
•
Touch the
or
To set a parameter:
•
Touch the
•
Touch the
or
•
Touch the
To exit the procedure:
•
Touch the
Parametri di configurazione
LABEL
MIN.
MAS.
SP
r1
r2
LABEL
MIN.
MAS.
CA1
-25
25
CA2
-25
25
CA3
-25
25
P0
0
1
P1
0
1
P2
0
1
P3
0
2
P4
0
3
P5
0
4
P7
0
100
P8
0
250
LABEL
MIN.
MAS.
r0
0.1
15
r1
-99
r2
r2
r1
99
r4
0
99
r5
0
1
r6
0
99
r7
0
240
r8
0
2
r12
0
1
LABEL
MIN.
MAS.
C0
0
240
C2
0
240
C3
0
240
C4
0
240
C5
0
240
key
key
key within 15 s.
key or do not operate for 15 s.
key for 4 s or do not operate for 60 s (any changes will be saved)
U.M.
WORKING SETPOINT
°C/°F (1)
working setpoint; see also r0 and r12
U.M.
WORKING SETPOINT
if P4 = 0, 1 or 2, room probe offset
°C/°F (1)
if P4 = 3, incoming air probe offset
°C/°F (1)
evaporator probe offset
if P4 = 1, condenser probe offset
°C/°F (1)
if P4 = 2, critical temperature probe offset
if P4 = 3, outgoing air probe offset
probe type
-
0 = PTC
1 = NTC
degree Celsius decimal point (during normal operation)
-
1 = YES
unit of measurement for temperature (2)
-
0 = °C (Celsius degree; resolution depends on P1 parameter)
1 = °F (Fahrenheit degree; resolution is 1 °F)
evaporator probe function
0 = absent probe
-
1 = defrost probe and probe determining the activity of the evaporator fan
2 = probe determining the activity of the evaporator fan
fourth inlet function
0 = multifunction input (digital input)
-
1 = condenser probe (analog input )
2 = critical temperature probe (analog input )
3 = outlet air probe (analog input ) (3)
magnitude displayed during normal operation
0 = if P4 = 0, 1 or 2, room temperature
if P4 = 3, CPT temperature
1 = working setpoint
2 = evaporator temperature
3 = if P4 = 0, "- - -"
-
if P4 = 1, condenser temperature
if P4 = 2, critical temperature
if P4 = 3, outlet air temperature
4 = if P4 = 0, 1 o 2, "- - -"
if P4 = 3, inlet air temperature
%
inflowing air temperature percentage for the calculation of the CPT temperature
0,1 s
delayed display of temperature changes as detected by the probes
U.M.
MAIN REGULATOR
°C/°F (1)
working setpoint differential; see also r12
°C/°F (1)
minimum working setpoint
°C/°F (1)
maximum working setpoint
working setpoint increase during the "energy saving" function; see also i5, i10 and HE2
°C/°F (1)
cooling or heating operation (4)
-
0 = cooling
1 = heat
if r5 = 0, working setpoint decrease during the "rapid cooling" function (only if r8 = 1); see also r7
°C/°F (1)
if r5 = 1, working setpoint increase during the "rapid heating" function (only if r8 = 1); see also r7
if r5 = 0, "rapid cooling" function duration (only if r8 = 1); see also r6
min
if r5 = 1, "rapid heating" function duration (only if r8 = 1); see also r6
this function can be enabled/disabled with the key
0 = none
1 = if r5 = 0, "Rapid cooling" function
-
if r5 = 1, "Rapid heating" function
2 = "energy saving" function (only if r5 = 0)
working setpoint differential type
-
0 = asymmetric
1 = symmetric
U.M.
COMPRESSOR PROTECTION SYSTEM
min
delay in switching on of compressor after the device switches on (5)
min
minimum compressor switch-off duration (6)
s
minimum duration of compressor switch on time
duration of compressor switch off time during a room temperature probe error or inlet air probe error
min
(code "Pr1"); see also C5
duration of compressor switch on time during a room temperature probe error or inlet air probe error
min
(code "Pr1"); see also C4
19