ELECTRICAL CONNECTION
The water purifier should be connected to an earthed electrical
supply. We recommend connection using a plug, as some op-
erations require the power supply to be temporarily interrupted.
The plug should also be easily accessible after installation.
1.
Connect the plug to the wall socket.
2.
The water purifier starts and flushes. The water puri-
fier conducts this flushing operation every time the
plug is connected.
The water may not be used until the flushing proce-
dure as described in the section
completed.
3.
Start purified water production and check that the
connections are watertight following installation. If
any of the connections leak, pull out the plug and
further tighten the hose clip or nut. Connect the plug.
4.
Post-tighten the reject water and feed water hoses
after one week's use.
A few drops of leakage at either end of the
purified water hose is sufficient for the water
purifier to start (involuntarily). Leakage outside
the water purifier cannot be discovered by its safety
system. Unless otherwise indicated, the shut-off valve
must always be open for the water purifier's safety
system to work.
INSTALLATION
FLUSHING
Flushing is performed when the water purifier:
First check that:
has been
FLUSHING
EN13
•
Is new and has never been used before.
•
Is reinstalled after having been in storage.
•
Has been cleaned, in order to rinse out the descaling agent.
•
Has been supplied with a new membrane.
Purified water may not be drunk/used before or
while flushing is in progress.
•
Purified water production has stopped.
•
The purified water hose is disconnected from any peripheral
equipment and routed to the reject water outlet.
•
The shut-off valve on the feed water pipe is open.
•
There are no leaks at the feed water connection.
•
The reject water and purified water connections are water-
tight.
•
The pre-filters are properly tightened.
1.
Pull the plug out of the wall socket.
2.
Connect the plug to the wall socket again. The water
purifier flushes automatically.
3.
Restart the water purifier so that it flushes automati-
cally by pulling out and reconnecting the plug again.
4.
Restart the water purifier one more time.
a) New installation or membrane replacement
5
Perform calibration according to the section
.
BRATION
b) Just flushing
Allow the water purifier to flush purified water to
the reject water outlet via the purified water hose.
If no tap is installed, this takes place automatically.
Pull out the plug after 10 minutes and connect the
purified water hose to any peripheral equipment. If
the tap is installed, open the tap and allow the water
purifier to produce purified water for 10 minutes.
Close the tap.
The water purifier is now ready to produce puri-
fied water.