Kongskilde CUC Manual Del Operador página 6

Idiomas disponibles
  • ES

Idiomas disponibles

Shortcut to overview screen
for user with "Admin" rights
Fault menu
Settings menu
Cleaning function*
Local / remote control
Setpoints
*: Cleaning function that closes the valve flap to maintain a constant suction down to the compactor pipe. As long
as the button is pressed, the flap remains closed. This may remove a plug of material that has accumulated in the
material pipe above the piston. The material feed to the trim handler should be stopped before using this function.
The main display is accessible to all users and is not provided with any language dependent texts.
6
MAIN DISPLAY
Setpoints status
1
2
Stop Start
Setpoint down Setpoint up
Fault menu
If a fault occurs in the frequency converter, this icon in the top left corner
will flash, changing from black to red. The error messages are sent from
the frequency converter control directly to the operator panel.
By pressing the icon, it is possible to read and reset the fault by pressing
Reset Faults. This can only be done as user Admin, and only if the fault
can be corrected by resetting.
The Frequency converter error field will display faults that would normally
cause a shutdown, such as overheating of the motor or converter.
The Frequency converter warning field will display errors that would not
normally cause a shutdown, such as a temperature increase above the al-
lowed temperature on the motor or converter.
If the field to the right of "Com faults" turns red, there is a communication
fault between the PLC and the connected components.
If the field to the right of "Frequency converter faults" turns red, there is a
fault on one of the motors, or possibly on a converter.
Filter alarm is shown in yellow to indicate that the alarm does not cause the
compactor to stop.
Exit the menu with Return and return to the main display.
Trim handler model
Software version
Operating status:
Lights green - trim handler is
operating
Flashing green - trim handler
has not yet reached set point
Red - trim handler has
stopped
3
4
Yellow with filter icon - one or
both filters are clogged
loading