Icon for status of digital inputs and outputs
The icon gives access to a status screen. It is not possible to manually cor-
rect the status of the digital inputs and outputs.
The screen on the left shows the status screen for the trim handler setup
where 1 setpoint is selected.
The top 6 icons show the digital outputs:
0
ON Trim handler running
OFF Trim handler stopped
1
ON Indicates a fault on the trim handler
OFF There is no fault on the trim handler
2
ON Indicates a warning on the trim handler
OFF Indicates no warning on the trim handler
3
ON Indicates that the valve flap is closed
OFF Indicates that the valve flap is open
4
ON Indicates that the retaining pins are up
OFF Indicates that the retaining pins are down
5
Not connected
The lower 8 icons show the digital inputs:
0
ON Start the trim handler
OFF Stop the trim handler
1
ON Indicates that the synchronisation sensor is activated*
OFF Indicates that the synchronisation sensor is disabled
2
ON Indicates that the retainer pin sensor is activated**
OFF Indicates that the retainer pin sensor is deactivated
3
ON Indicates that safety switches are enabled
OFF Indicates that safety switches are deactivated
4
ON Indicates that the pre-filter pressure switch is activated
OFF Indicates that the pre-filter pressure switch is deactivated
5
ON Indicates that main filter pressure switch is activated
OFF Indicates that the main filter pressostat switch is deactivated
6
Not connected
7
Not connected
*: The synchronisation sensor is located on the piston gear mechanism, and
ensures synchronisation with the valve flap and retaining pins.
**: The retainer pin sensor is located on the retainer pin cylinder and en-
sures synchronisation with the valve flap and piston.
11