ADVICE
PIPE SUPPORTS
All sanitary pipe work must
be supported, in accordance
with the pipe manufacturers
recommendations, to avoid dipping,
which may cause the build up of
residual water and subsequent
blockage.
BENDS
Where possible long sweeping
bends should be used rather than
elbows. If this is not possible, It
is recommended to use two 45°
elbows rather than one 90° elbow.
VERTICAL INSTALLATION FIRST
If vertical lift is required, this must
precede the horizontal pipe run.
The vertical discharge pipe should
first bypass the bowl, do not extend
the horizontal portion of the pipe
for more than 12-18 inches.
EASY ACCESS
The unit should be accessible
and removable in the event of
maintenance being required. During
the installation a full-port gate valve
should be fitted at the base of any
vertical discharge pipe work from
the unit to allow easy removal of
the unit without flooding.
GRAVITY FALL
Horizontal discharge pipe work
must also have a positive gravity
fall to allow free drainage when the
pump stops.
THREE FEET MINIMUM
The macerating/pump must have
at least 3 feet of total pipe run in
between the pump and soil stack.
This will cause the macerator to
operate for an adequate period of
time to ensure waste reduction.
SOIL STACK CONNECTION
This unit must discharge into a
minimum 3-inch sanitary drainage
pipe.All discharge pipe work must
be connected to the soil stack by
an appropriate and approved TY
connection. Please note: the use of
a Saddle Clip may be prohibited in
your area.
NO DIAGONAL "UPHILL" PIPE
RUNS
All discharge pipe work from the
unit should run either directly
vertical upwards from it or in a
horizontal plane (with a small
gravity flow) to the point of
discharge. Pipe work should not
be installed with diagonal upward
slope from the unit.
PIPE WORK
All pipe work should be either
copper or solvent weld plastic
(PVC, CPVC). Do not use flexible
pipes.
DISCHARGE
Never discharge directly into an
open drain, manhole or rainwater
drain pipe. It is illegal.
10
FREEZING
Ensure all pipe work susceptible
freezing is adequately insulated.
The toilet and macerating/pump
unit must be properly winterized
in unheated buildings.
ELECTRICITY
Before attempting any maintenance
or servicing, the unit must be
disconnected from the power source.
The Sanicompact® 4C must be
connected to a Ground Fault Circuit
Interrupter and be supplied with
120V, 60Hz.
VIII
LIMITED WARRANTY
2 Year Warranty from Date of
Purchase
A. GENERAL
Subject to the terms and conditions
set out in this document, SFA-
SANIFLO INC., hereafter designated
as the Company, guarantees the
consumer to repair or exchange any
product or any of its components
(at the discretion of SFA Saniflo Inc)
which proves to be defective.
• First (1
) year: will only cover
st
"exchanges" starting from the
date of purchase.
• Second (2nd) year: will only
cover "repairs" or will provide
"replacement parts" at no charge
for the remainder of product's
warranty period.
B. TERMS AND CONDITIONS
1. The product must be installed and
used as per instructions supplied
and indicated in the product
manuals. This is not limited to but
includes the product:
n o t b e s u b j e c t e d t o a n y
negligence, accident or exposure
t o
" h a r m f u l "
p r o d u c t s
substances.
installed in strict accordance
with local state or provincial
electrical and plumbing codes.
2. The alleged defect or fault must
be reported either to the product
installer or the company within the
:
NOTE
o r
loading