Description
The temperature inside electronic components compartment (on the right hand
side of the oven) is too high and can damage the integrity of the components.
Oven functioning
If the oven is cooking, it stops.
It's not possible to keep on using the oven.
Resetting
The oven will be operative again, when the temperature will be lower than the
selected value.
Suggestions for the operator
Check the ventilation holes under the control panel (next to USB and core probe
connector) are not obstructed. Check the ventilation holes on the right hand side
panel are not obstructed and that the air can pass through these holes.
If the problem persists, call the technical service.
Remarks for the technical service
Check the functioning and the connections of the cooling fan for the components compartment.
Ensure there are not hot sources next to the right hand side of the oven (we recommend a minimum distance
of 50 cm). Check the ventilation holes are not obstructed by grease or dust.
7.2 NOT SERIOUS ALARMS
Description
The core probe doesn't work properly.
It's not possible to use this device.
Oven functioning
It's possible to use the oven with time control of the cooking.
It's not possible to use automatic programs including one or more phases con-
trolled by the core probe.
Resetting
The oven can work with core probe again, when the core probe is functioning
correctly again.
Suggestions for the operator
Check the core probe is properly connected to the oven.
Check the cable and the skewer are integral
If the problem persists call the technical service.
Remarks for the technical service
Check the functioning of the core probe (the reading of the heating element in ohm of the probe must be 1000
+ room temperature). If necessary, replace the core probe.
23
EN
Code A090
ATTENTION!
HIGH TEMPERATURE
ELECTRONIC DEVICES
COMPARTMENT
SWITCH OFF THE OVEN
IF AFTER ONE HOUR
THE MALFUNCTIONING
DOESN'T DISAPPEAR
CALL TECHNICAL SERVICE
Code A210
ATTENTION!
CORE PROBE
MALFUNCTIONING
DISCONNECT CORE
PROBE
IT IS POSSIBLE TO KEEP
ON
COOKING ONLY USING
TIME CONTROL
REPLACE CORE PROBE