EU
Communication error
Code
Temperature sensor error - open
E1
circuit
Temperature sensor error - short-
E2
circuit
Eb
Temperature sensor error
E3
Sensor temperature too high
IGBT temperature sensor error -
E4
Open circuit
IGBT temperature sensor error -
E5
Short-circuit
E6
IGBT temperature too high
Supply voltage is lower than the
E7
rated voltage.
Supply voltage is higher than the
E8
rated voltage.
U1
Communication error
Code
Supply voltage is higher than the correct
E1
voltage.
Supply voltage is lower than the correct
E2
voltage.
E3
Sensor temperature too high
E4
Sensor temperature too high
E5
IGBT temperature too high
E6
IGBT temperature too high
Problem
I603T
Problem
I603F
SELF-RECOVERY
Reattach the connection between the
power supply panel and the display
Solution
Check the connection or replace the hob's
temperature sensor
Wait until the IGBT temperature returns to
normal Use the "ON/OFF" control to restart
the appliance. Check that the fan is working
correctly. Otherwise replace the fan.
Replace the power supply board.
Wait until the IGBT temperature returns to
normal Use the "ON/OFF" control to restart
the appliance. Check that the fan is working
correctly. Otherwise replace the fan.
Check to see whether the power supply is
normal. Switch on after the power supply
returns to normal.
Reattach the connection between the power
supply panel and the display
Check to see whether the power
supply is normal.
Switch on after the power supply
returns to normal.
Wait for the hob temperature to
return to normal.
Touch the "ON/OFF" button to
restart the unit.
Wait until the IGBT temperature
returns to normal
Touch the "ON/OFF" button to
restart the unit.
Check if the fan operates correctly;
If not, replace the fan.
Solution