Interrupting The Charging Process; Resuming Charging - Fronius XCharge_professional Manual De Instrucciones

Sistema de carga de baterías
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5
The charger automatically recognises the connected battery and starts the charging pro-
cess after approximately 5 seconds.
If the device remains in standby when the battery is connected, then the battery is in a state
of extreme deep discharge (< 2 V).
7
Interrupting the
charging process
Resuming charg-
ing
64
Connect the battery, observing the correct polarity. Because the charging terminals
are de-energised, there is no risk of sparks when connecting to the battery, even if the
charger is already connected to the mains supply.
-
Connect the red charging lead to the positive pole (+) of the battery
-
Connect the black charging lead to the negative pole (-) of the battery
CAUTION! Risk of sparks if the charging leads are disconnected too soon. Before
disconnecting the charging leads, press the Stop/Start key to end the charging
process.
6
Disconnecting the charger
-
Disconnect the black charging lead from the negative pole (-) of the battery
-
Disconnect the red charging lead from the positive pole (+) of the battery
NOTE! Risk of damage to connection sockets and connecting plugs. Do not dis-
connect or unplug charging leads while charging.
1
2
For battery voltages lower than 8.4 V, a
message appears recommending the use
of Pb Refresh mode.
To end the charging process:
-
Press the Stop/Start key
Press the Stop/Start key while charging
-
The charging process is interrupted
Press the Stop/Start key
-
The charging process is resumed
Tabla de contenido