The data given represents the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools or is poorly maintained, the data may vary. This may
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the power tool is switched
off, or when it is running but not actually being used for a job. This may significantly reduce exposure over
the total working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise emission values
Sound (power) level
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Total vibration
Other applications, such as cutting, may produce vibration values that deviate from the given values.
Surface grinding with the vibration-absorbing side handle (a
Uncertainty (K)
6

Preparations at the workplace

CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
6.1
Fitting the guard or guard with cover plate
The keying on the guard ensures that only a guard designed for use with the power tool can be fitted.
The keyed locating lug also prevents the guard from coming into contact with the disc.
1. Release the clamping lever.
2. Fit the guard onto the spindle collar so that the keyed locating lug engages in the recess provided.
3. Rotate the guard to the required position.
4. Secure the guard by closing the clamping lever.
The guard is already set to the correct tension by way of the adjusting screw. If the tension is too
low when the guard is fitted, the adjusting screw can be tightened slightly to increase the tension.
6.2
Adjusting the guard or guard with cover plate
1. Release the clamping lever.
2. Rotate the guard to the required position.
3. Secure the guard by closing the clamping lever.
6.3
Removing the guard or guard with cover plate
1. Release the clamping lever.
2. Rotate the guard until the keyed locating lug is aligned with the keyed locating groove and then remove
the guard.
6.4
Fitting the side handle
▶ Screw the side handle into one of the threaded bushings provided.
71878
*71878*
Printed: 29.03.2018 | Doc-Nr: PUB / 5069492 / 000 / 03
)
pA
)
pA
3
4
DCG 180-D/P
101 dB(A)
90 dB(A)
3 dB(A)
DCG 180-D/P
)
6.0 m/s²
h,AG
1.5 m/s²
English
23

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Dcg 180-p

Tabla de contenido