Hilti DX 351-CT Manual De Instrucciones Original página 20

Ocultar thumbs Ver también para DX 351-CT:
Idiomas disponibles

Idiomas disponibles

9.3
Problems with the cartridges
Malfunction
The cartridge strip doesn't
advance
Cartridge strip is difficult to
remove.
The cartridge doesn't fire
The cartridge strip melts
A cartridge detaches itself
from the cartridge strip
10
Disposal
Most of the materials from which Hiltiproducts are manufactured can be recycled. The materials must be
correctly separated before they can be recycled. In many countries, your old tools, machines or appliances
can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative for further information.
14
English
Possible cause
The cartridge strip is damaged.
Fastening tool damaged.
Wrong cartridge strip used
Fastening tool not fully pressed
Fastening tool overheated.
Build-up of combustion residues.
Bad cartridge.
Fastening tool dirty.
Fastening tool was not pressed
fully against the working surface.
Wrong combination of fastener,
fastener guide, etc.
Fastening tool was pressed against
the surface for too long without a
fastener being fired.
Fastener driving rate too high (fas-
tening tool overheated).
Fastener driving rate too high (fas-
tening tool overheated).
Action to be taken
▶ Change the cartridge strip.
▶ Contact Hilti Service.
▶ Use only cartridge strips of a
type intended for use with the
fastening tool.
▶ After positioning the fastening
tool, press it against the base
material and fire the fastener
right away.
▶ Allow the fastening tool to
cool down under constant
observation.
▶ Subsequently, carefully remove
the cartridge strip from the
fastening tool.
▶ Service the tool.
▶ Insert new cartridge strip.
▶ Pull the cartridge strip through
to the next cartridge.
▶ Service the tool.
▶ Press the fastening tool fully
against the working surface.
▶ Check that the combination of
fastener, fastener guide, etc. is
correct for your application.
▶ After positioning the fastening
tool, press it against the base
material and fire the fastener
right away.
▶ Stop using the tool immediately.
▶ Remove cartridge strips and
allow the fastening tool to cool
down.
▶ Do not exceed the recom-
mended maximum fastener
driving rate (see the section
headed "Technical data").
▶ Stop using the tool immediately.
▶ Remove cartridge strips and
allow the fastening tool to cool
down.
▶ Do not exceed the recom-
mended maximum fastener
driving rate (see the section
headed "Technical data").
388037
*388037*
loading