Track mode:
The currently applied torque is shown on the display. The PH display
on the right next to the numbers is hidden.
Peak Hold mode:
The highest applied torque is shown on the display. The PH display
on the right next to the numbers is visible.
First Peak mode:
The torque on triggering (Click) is shown on the display. FP is shown
on the left next to the numbers. The PH display on the right next to
the numbers is visible.
To set the desired mode, proceed as follows:
➢ Press the "MODE" button until the desired mode is shown on the
display.
The last setting carried out is stored and is available when the
DPG is next switched on.