Instructions For Use; Description/Intended Use - Dräger f2-PA Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
f2- PA- RA
Full-face mask with round
thread connection
For your Safety
Strictly follow the Instructions for Use
Any use of the mask requires full understanding and strict observation
of these instructions. The mask is only to be used for purposes
specified here.
Maintenance
See "Maintenance Intervals". Only authentic Dräger spare parts may be
used for maintenance. We recommend that you take out a service
contract with Dräger Service.
Liability for proper function or damage
The liability for the proper function of the mask is irrevocably transferred
to the owner or operator if the mask is serviced or repaired by
personnel not employed or authorised by DrägerService or if the mask
is used in a manner not conforming to its intended use.
Dräger cannot be held responsible for damage caused by non-
compliance with the recommendations given above. The warranty and
liability provisions of the terms of sale and delivery of Dräger are
likewise not modified by the recommendations given above.
Dräger Safety AG & Co. KGaA
Designations
These Instructions for Use apply to masks with the following type
identity markings:
f2- SI/ I- PA- RA
f2- EPDM/ I- PA- RA
Externally legible markings: f2 on the mask sealing piece, Si or EPDM
outer left, I on the inner mask, PA on inside of visor, RA on mask
connector.
CE symbol on mask body:
EN 136 CL 3, ID No. 0158
What's what
1 Mask connector
5 Steel wire
2 Control valve
6 Harness
3 Inner mask
7 Sealing piece
4 Visor
8 Mask body
11
5
4
3
2
1
9
10
8

Description/Intended use

The above full-face masks are facepieces conforming to EN 136 Cl.3
and are marked with the CE symbol. In addition, the full-face masks
satisfy the requirement of total flame engulfment conforming to EN 137.
Each mask consists of the visor (hard body) and sealing piece (soft
body). They protect the wearer's face and eyes against aggressive
media.
For users who wear spectacles, mask goggles may be used.
Operating temperature: –30 °C to 120 °C
Only use with normal pressure compressed air line breathing apparatus
or respiratory filters with round thread conforming to EN148 Part 1.
4
9 Clasp
10 Protective cap
11 Top head strap
fastening
6
7
Use
Preparing the mask: Open the straps of the harness as far as they will
go. Place the carrier strap around your neck, and button it into the top
head strap fastening.
Fitting the mask: Beards and sideburns in
the sealing area of the face mask will cause
leaks. Therefore the full-face mask should not
be used by anyone with facial hair of this sort.
Spectacle frames in the sealing area also
cause leaks. Use special mask goggles.
Unbutton the carrier strap. Place chin in chin-
piece.
Fit the harness over the head, pulling back
until the head strap fits smoothly. Adjust mask
until it fits properly.
1 Tighten neck straps evenly
2 Tighten temple straps evenly
3 If necessary, in particular if the wearer's
head is small, also tighten the top head
strap.
Leak test: Seal off the mask connector and breathe in until negative
pressure (suction) is generated. Hold your breath for a moment. The
negative pressure should be maintained. If not, retighten the straps.
Repeat the leak test twice. Never use a mask that leaks!
Exhalation valve check: Seal off the mask connector and exhale
vigorously. The exhaled air must be able to escape without obstruction.
If not, see "Visual inspection of exhalation valve".
Connect the compressed air breathing apparatus or respiratory
1)
filter
.
Operation with respiratory filter
Preconditions: The ambient air must contain at least 17 Vol.% oxygen.
Do not enter non-ventilated containers, pits, drains etc. with filter
devices. The type of pollutant must be known, and the appropriate
respiratory filter must be used.
Screw in the respiratory filter: Fully remove the sealing strips and
screw the respiratory filter in firmly by turning it clockwise.
Operating time: The permitted intervention time depends on various
factors, including the type and concentration of pollutant and the type
of filter.
Extreme operating conditions:
In case of low temperatures: Protect the inside of the visor with
"klar-pilot" anti-misting gel to prevent it from fogging up
In case of high temperatures: If the visor is damaged, leave the
danger zone immediately.
In the presence of chemicals: Certain substances such as H
phosgene may be absorbed by the materials of the full-face mask,
especially silicone, or may diffuse through it.
In explosion-hazard areas: Treat the full-face mask with antistatic
spray or work with a screen of mist water.
After use
Remove demand valves or respiratory filter
1)
Dispose of the respiratory filter
Removing mask: Insert your index finger
behind the tabs on the neck straps and press
the clamping buckles forward with your
thumb while at the same time pulling the mask
off your face and back over your head.
Cleaning, disinfecting, drying
Only use authorised cleaning and disinfecting agents.
Cleaning: The mask must be cleaned after every use. Do not use any
solvents such as acetone, alcohol etc. Clean the mask with a cloth and
lukewarm water mixed with all-purpose detergent, e.g. Sekusept
1)
Cleaner
(Order No. 79 04 071). Rinse thoroughly under running
water.
Disinfecting: Disinfect the mask after each use. Immerse the mask in a
disinfectant bath. Use only approved disinfectants, e.g. Incidur
No. 79 04 072). Excessive disinfectant concentrations and over-long
disinfecting times can damage the mask. Rinse thoroughly under
running water.
Machine cleaning and disinfecting with Eltra:
Order No. 79 04 074 – as per Instructions for Use 90 21 380.
Drying: Leave to dry in a drying cabinet R 28 305 or in air. Max.
temperature 60 °C. Do not expose to direct sunlight.
1) Follow the specific Instructions for Use of the product.
3
1)
.
S and
2
1)
.
.
1)
(Order
2
1
Tabla de contenido
loading

Este manual también es adecuado para:

F2-ra

Tabla de contenido