PERFORMANCE & SPECIFICATIONS
SPECIFICATIONS
Power supply required..............................................................................................................................115V, 60 HZ., 15 Amp Circuit
Liquid temp. range...................................................................................................................................32°F to 70°F (0°-21°C)
Individual branch circuit eequired (min.)...................................................................................................15 Amps
Discharge.................................................................................................................................................1-1/2" Female NPT
NOTE: Do not reduce size of discharge pipe or hose below 1-1/4" diameter. If discharge is too small, pump will overheat and fail prematurely.
PERFORAMCE
SERIES
0 FT
6660
MSZ100V10-R
(25211)
ELECTRICAL & SWITCH SPECIFICATIONS
SERIES
HP
MSZ100V10-R
1
6
GPH (LPH) at total feet of lift
5 FT
10 FT
CAPACITY GALLONS/HOUR
5880
4980
(22258)
(18851)
INDIVIDUAL
MOTOR FULL
BRANCH CIRCUIT
LOAD AMPS
REQ. (AMPS)
7.9
15
15 FT
20 FT
4020
2880
(15217)
(10902)
SWITCH SETTING IN INCHES
WATER LEVEL FOR:
ON
OFF
7 1/2"
3"
NO FLOW AT
HEIGHT SHOWN
25 FT
BELOW IN FEET
(METERS)
1500
29'
(5678)
(9)