Time Setting - Unox ChefTop XK304 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
3.5 MANUAL FUNCTIONING
Any blast chilling / shock freezing program may be com-
posed of 4 steps.
To pass from one step to another touch the
the selected step is indicated by the illuminated led.
For each step the user can set the following settings:
time or, as an alternative, core temperature
chamber temperature or, as an alternative, Delta T
(available only if core temperature is set)
To pass from one setting to another press the
ton. The selected setting is indicated by one of the illumi-
nated icons
TEMPERATURE
TEMPS
TEMPERATURA
TEMPO
CŒUR
The settings "TIME" and "CORE TEMPERATURE" are
self cancelling: when selecting the "TIME", the "CORE
TEMPERATURE" setting will be inoperable; vice ver-
sa, when selecting the "CORE TEMPERATURE" , the
"TIME" setting will be inoperable.
The "CHAMBER TEMPERATURE" and "Delta T" settings
are also self cancelling: when selecting the "CHAMBER
TEMPERATURE", the "Delta T" setting will be inoper-
able; vice versa, when selecting "Delta T", the "CHAM-
BER TEMPERATURE" setting will be inoperable.
It is essential to select either the "TIME" or the "CORE
TEMPERATURE" setting: if none of these selections are
set, the control board does not allow the user to select
button:
TEMPERATURE
TEMPERATURA
DELTA T
DELTA T
CUORE
CAMERA
CHAMBRE
T
any of the following (cavity temperature, Delta T, Cli-
mate).

Time setting

The time is shown on the display panel 1 and is set with
the buttons
When the display panel shows "
work continuously until it is manually stopped by the
user.
inF
Core temperature setting
The core temperature is shown on display panel 1 and is
but-
set with the buttons
During the blast chilling / shock freezing cycle, if the core
temperature has been set, the display panel 2 shows,
alternatively, the set temperature and the temperature
taken by the core probe (flashing display panel).
The step is completed when the set core temperature is
reached, then the cycle passes to the next step (if set).
-20°C
UNO X
", the blast chiller will
INF
0h 00'
9h 59'
+10°C
ENGLISH
R
4