Stenner Pumps S Serie Manual De Instalación Y Mantenimiento página 51

Dosificador peristáltico
Ocultar thumbs Ver también para S Serie:
Idiomas disponibles

Idiomas disponibles

CONTROL MODES MENU
PPM FEED – VARIABLE FLOW, HALL EFFECT
• The pump provides +12VDC to the meter.
• The meter's K factor (pulses per unit of volume) is specified by the meter manufacturer.
• Typically, the meter manufacturer specifies a minimum flow rate for the meter. The pump minimum process flow rate
setting should not be set below the meter manufacturer's recommendation.
NAVIGATION
Moves up in a menu, toggles
between options, or increase a value
Holding the
or
button causes the numbers to change rapidly.
Continued from previous page
PPM Feed Variable Flow
- Program Settings
- Alarm Settings
- Go to PPM Feed Menu
S Series FW 4.01.02 US and Canada 800.683.2378, International 904.641.1666 www.stenner.com
continued
Moves down in a menu, toggles
between options, or decreases a value
Meter K Factor P/G
1000.0000
adjust
Concentration
100.00 %
yes/no
Specific Gravity
1.14
adjust
Feed Rate
_ 10.0 PPM
adjust
Go to top of
PPM Variable Flow menu
51
page 6 of 6
Moves one step back in
a menu, when permitted
Set the Meter K Factor.
Gallons or Liters is selected in
Units under Configuration.
set
Set the Chemical Concentration.
set
Set the Chemical Specific Gravity.
set
Set the dose rate in parts per
million (ppm).
set
Sets a value in a menu