Mitsubishi Electric Mr.SLIM MSH24WN Manual De Instrucciones página 14

Idiomas disponibles

Idiomas disponibles

WHEN YOU THINK THAT TROUBLE HAS OCCURRED
Question
The sound as
burbling is heard.
The room cannot
be cooled
sufficiently.
The air flow
direction changes
during operation.
Water leaks from
the outdoor unit.
Air does not blow
out soon in the
heating operation.
14
Get user manuals:
See SafeManuals.com
Answer (not a malfunction)
I This sound is heard when the outside air is absorbed
from the drain hose in turning on the range hood or
the ventilation fan and that makes water flowing in the
drain hose spout out.
This sound is also heard when the outside air blows
into the drain hose in case the outside wind is strong.
I When a ventilation fan or a gas cooker is used in a
room, the cooling load increases, resulting in an in-
sufficient cooling effect.
I When the outside air temperature is high, the cooling
effect may not be sufficient.
I When the air conditioner is operated in COOL or DRY
mode, if the operation continues with air blowing down
for 1 hour, the direction of the air flow is automatically set
to horizontal to prevent condensed water from dropping.
I In the heating operation, if the air flow temperature is
too low or when defrosting is being done, the HORI-
ZONTAL VANE position is automatically set to hori-
zontal.
I During COOL and DRY operations, pipe or pipe con-
necting sections are cooled and this causes water to
condense.
I In the heating operation, the defrosting operation makes
water frozen on the outdoor unit melt and drip down.
I In the heating operation, water condensed on the heat
exchanger drips down.
I Please wait as the air conditioner is preparing to blow
out warm air.
Question
I Defrosting of the outdoor unit is being done (Defrost-
The operation is
ing operation).
stopped for about
Since this is completed in 10 minutes, please wait.
10 minutes in the
(When the external temperature is too low and humid-
heating operation.
ity is too high, frost is formed.)
I This is the sound when the flow of refrigerant inside
Hissing sound is
sometimes heard.
the air conditioner is switched.
The room cannot
I When the outside air temperature is low, the heating
be heated
effect may not be sufficient.
sufficiently.
The swing
operation of the
I This is for the swing operation of the VERTICAL VANE
VERTICAL VANE is
suspended for
to be performed normally.
about 15 seconds,
then restarted.
The air conditioner
I This model is equipped with an auto restart function.
starts the operation
When the main power is turned off without stopping
only with the main
the air conditioner with the remote controller and is
power turned on,
turned on again, the air conditioner will start opera-
though you do not
tion automatically in the same mode as the one set
operate the unit
with the remote controller just before the shutoff of
with the remote
the main power.
controller.
Answer (not a malfunction)
loading