Vaillant sensoCOMFORT VRC 720/3 Manual De Uso E Instalación página 65

Idiomas disponibles

Idiomas disponibles

Air quality limit: ppm
Ventilation boost
Humidity prevention
Max. room air humidity: %rel
Time programme assistant
Green iQ:
Installation off
2.14.2 Menu item INFORMATION
MENU
INFORMATION
Ext. power reduction:
Ext. energy manager status:
Current temperatures
Zone
DHW temperature
DHW circuit 1
Water pressure: bar
Current room air humidity
Energy data
Solar yield
Environmental yield
Power consumption
Heating
DHW
Cooling
Installation
Fuel consumption
0020287900_03 Operating and installation instructions
The ventilation unit keeps the CO
the set value.
Heating mode is switched off for 30 minutes and, if available, the
ventilation unit runs at the highest ventilation level.
When the Max. room air humidity: %rel is exceeded, the dehu-
midifier switches on. If the value is not reached, the dehumidifier
switches off.
Target value for the humidity prevention function
Programming of the desired temperature for Monday–Friday and
Saturday–Sunday; the programming applies for the time-controlled
Heating Cooling, DHW, Circulation and Ventilation functions
Overwrites the weekly planner for the Heating, Cooling, DHW,
Circulation and Ventilation functions
Switching on the most energy-efficient heating mode, if your install-
ation supports this.
Installation is switched off. Frost protection and, if available, ventil-
ation remain activated at the lowest level.
Display whether a signal from the energy supply company about
the power reduction for your installation is active, inactive or not
available.
Active means: The external Energy Manager has taken over the
control. The system control displays a reduced selection of func-
tions.
Current room temperature in the zone
Current temperature in the domestic hot water cylinder
Current temperature in domestic hot water cylinder circuit 1
Current water pressure in the heating installation
Current room air humidity, measured using the installed humidity
sensor
Display of the energy consumption, energy yields and efficiencies
App, boiler and system control display estimated values for energy
consumption, energy yields and efficiencies based on an extrapol-
ation. The displayed values in the app may differ based on the dif-
ferent update intervals when compared to the displays in the con-
trol panels for the boilers and system control.
Among other things, the values depend on:
Installation and type of heating installation
User behaviour
Seasonal influences
Tolerances and components
External consumers and generators in the household (e.g. ext.
heating pumps or valves) are not taken into consideration.
Deviations between the displayed values and the actual values
may be considerable; the specifications are therefore not suitable
to be used to create or compare energy billing.
Energy yield of the connected solar system
Energy yield of the heat source installation for the connected heat
pumps
The installation's electrical energy consumption based on the re-
spective system function and/or the overall installation
Current month, Last month, Current year, Last year, Total
Current month, Last month, Current year, Last year, Total
Current month, Last month, Current year, Last year, Total
Current month, Last month, Current year, Last year, Total
The installation's fuel consumption based on the respective system
function and/or the overall installation
content in the room air below
2
65