Vaillant sensoCOMFORT VRC 720/3 Manual De Uso E Instalación página 70

Idiomas disponibles

Idiomas disponibles

FM5 configuration:
FM3 configuration:
FM5 MO:
FM3 MO:
HP control module configuration
MO 2:
MI:
Not connected
1 x circulation
Photovoltaics
Ext. cooling mode
Heat generator 1
Status:
Current flow temperature: °C
Heat pump 1
Status:
Current flow temperature: °C
HP control module
Status:
Current flow temperature: °C
Circuit 1
Circuit type:
Inactive
Heating
Fixed value
DHW
Increase in return
Status:
Target flow temperature: °C
Actual flow temperature: °C
70
Each configuration corresponds to a defined FM5 terminal assign-
ment (→ Section 4.5). The terminal assignment determines which
functions contain the inputs and outputs.
Select the configuration that suits the installation that is installed.
Each configuration corresponds to a defined FM3 terminal assign-
ment (→ Section 4.6). The terminal assignment determines which
functions contain the inputs and outputs.
Select the configuration that suits the installation that is installed.
Select the multi-function output's function assignment.
Select the multi-function output's function assignment.
Select the multi-function output's function assignment.
Factory setting: Circulation pump
The system control queries whether a signal is present at the heat
pump's input. For example:
aroTHERM input: MI for the heat pump appliance interface
flexoTHERM input: X41, terminal in the functional drawing
Factory setting: 1 x circulation
The system control ignores the signal present.
The end user has pressed the circulation button. The system con-
trol activates the circulation pump for a short time period.
In the case of excessive current, a signal is present and the sys-
tem control activates the Hot water boost function once. If the sig-
nal persists, the buffer cylinder is charged to the flow temperature
+ buffer cylinder offset until the signal at the heat pump drops off
again.
The signal of an external control is used to switch between heating
and cooling.
MI contact closed = cooling
MI contact open = heating
Display of the current control command at the heat generator
Display of the current heat generator flow temperature
Display of the current control command at the heat pump
Display of the current heat pump flow temperature
Display of the current control command at the back-up boiler that
is connected to the heat pump appliance interface.
Display of the current flow temperature of the back-up boiler that is
connected to the heat pump appliance interface.
Value setting: Heating
The heating circuit is not being used.
The heating circuit is being used to heat and is weather-com-
pensated. Depending on the basic system diagram, the heating
circuit may be a mixing circuit or a direct circuit.
The heating circuit is used for heating and is maintained at a fixed
target flow temperature.
The heating circuit is being used as a domestic hot water circuit for
an additional cylinder.
The heating circuit is used for the increase in return. The increase
in return prevents an excessive temperature difference between
the heating flow and return, and protects against corrosion in the
floor-standing boiler when the dew point is not reached for an ex-
tended period.
Display of the current operating mode
Target value for the heating circuit flow temperature
Display of the current heating circuit flow temperature
Operating and installation instructions 0020287900_03