lIFtInG
Always use two people when lifting and lift
from the recommended lift points (N). DO
NOT lift by wheels or shroud.
MOVInG
CAUTION: The wheels and handle do not
provide adequate clearance, stability, or sup-
port for pulling the unit up and down stairs or
steps. The unit must be lifted or pushed up
a ramp.
1. Grasp handle of compressor and tilt com-
pressor back to rest on wheels.
WARNING: Risk of Unsafe Operation. Ensure proper footing and
use caution when rolling compressor so that unit does not tip or
cause loss of balance.
2. When location is reached slowly lower compressor to ground.
Always store compressor in a vertical position resting on
the rubber bumpers and wheels.
PrEPArATION FOr uSE
Pre-Start Checklist (Fig. 1)
1. Ensure the Auto/Off switch (A) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle.
See Voltage and Circuit Protection under Installation.
3. Ensure air tank is drained, see Draining Air tank under
Maintenance.
4. Ensure the drain valve (H) is closed.
5. Ensure safety valve (G) is functioning properly, see Checking
safety Valve under Maintenance.
6. Pull the regulator knob (D) out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi. Push knob
in to lock in place.
7. Attach hose and accessories. nOte: Always use a minimum
N
3/8" (9.5 mm) or greater air hose rated at 300 psi.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
WARNING: Risk of unsafe operation. Do not use damaged or worn
N
accessories.
WARNING: Risk of Bursting. Too much air pressure causes a
hazardous risk of bursting. Check the manufacturer's maximum
pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.
Initial Set-up (Fig. 1)
WARNING: Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance
instructions.
BreAk-In PrOCeDure
NOTICE: Risk of property damage. Serious damage may result if the
following break-in instructions are not closely followed.
This procedure is required before the air compressor is put into
service for the first time and when the check valve or a compressor
pump/motor has been replaced.
1. Ensure the Auto/Off switch (A) is in the OFF position.
nOte: If hose is not connected to Quick Connect body, pull coupler
back until it clicks to prevent air from escaping through the quick
connect.
2. Plug the power cord into the correct branch circuit receptacle. See
Voltage and Circuit Protection under Installation.
12