CODe
POssIBle CAuse
15
Tank pressure exceeds pressure switch cut-in
pressure
16
Extension cord is wrong length or gauge
17
Loose electrical connections
18
Possible defective motor
19
Paint spray on internal motor parts
20
Fuse blown, circuit breaker tripped
21
Worn Belt
22
Restricted air intake filter
23
Pressure release valve on pressure switch has not
unloaded head pressure
POssIBle sOlutIOn
Motor will start automatically when tank pressure drops below cut-
in pressure of pressure switch.
Check for proper gauge wire and cord length refer to the extension
Cords under Installation.
Check wiring connection inside pressure switch and terminal box
area.
Contact a D
WALT factory service center or a D
e
service center.
Contact a D
WALT factory service center or a D
e
service center. Do not operate the compressor in the paint spray
area. See risk of explosion or Fire warning under Important
Safety Instructions.
1. Check fuse box for blown fuse and replace as necessary. Reset
circuit breaker. Do not use a fuse or circuit breaker with higher
rating than that specified for our particular branch circuit.
2. Check for proper fuse. You should use a time delay fuse.
3. Check for low voltage conditions and/or proper extension cord.
4. Disconnect the other electrical appliances from circuit or operate
the compressor on its own branch circuit.
Contact a D
WALT factory service center or a D
e
service center.
Clean or replace air intake filter. Do not operate the air compressor
with the filter removed. Refer to the Air Filter paragraph in the
Maintenance section.
Bleed the line by pushing the lever on the pressure switch to the OFF
position; if the valve does not open, replace switch.