EN (Translation of the original language)
13
EVERY DAY USE
USE
1
If flexible pipes are used, attach the ends of the piping to the tanks. In the absence
PROCEDURE
of an appropriate slot, solidly grasp the delivery pipe before beginning dispensing.
2
Before starting the pump make sure that the delivery valve is closed (dispensing
nozzle or line valve)
3
Turn the ON/OFF switch on
4
Open the delivery valve, solidly grasping the pipe
5
While dispensing, do not inhale the pumped product
6
IF ANY TREATED FLUID LEAKS OUT DURING DISPENSING, TAKE ALL STEPS
NECESSARY TO ENSURE THE LEAKED FLUID IS CLEANED UP AND SAFE AS
SPECIFIED ON THE PRODUCT TECHNICAL SHEET.
7
Close the delivery valve to stop dispensing
8
When dispensing is finished, turn off the pump
WARNING
14
MAINTENANCE
Safety instruc-
The PUMP IS DESIGNED AND CONSTRUCTED TO require a minimum of maintenance.
Before carrying out any maintenance work, DISCONNECT THE PUMP from any elec-
tions
trical and hydraulic power source.
During maintenance, the use of personal protective equipment (PPE) is compulsory.
In any case always bear in mind the following basic recommendations for a good func-
tioning of the pump
WARNING
Authorised
All maintenance must be performed by qualified personnel. Tampering can lead to
maintenance
performance degradation, danger to persons and/or property and may result in the
personnel
warranty and UL/ATEX CERTIFICATION being voided.
Measures to
Check that the labels and plates found on the dispensing system do not deteriorate or
be taken
become detached over time.
ONCE A
- Check that the pipe connections are not loose to prevent any leaks;
WEEK:
- Check and keep the filter installed on the suction line clean.
ONCE A
- Check the pump body and keep it clean and free of any impurities;
MONTH:
- Check that the electrical supply cables are in good condition.
This manual belongs to PIUSI S.p.A. Whole or partial reproduction of this manual is forbidden.
THE WORKING OPERATIONS MUST ALWAYS BE GUARDED BY THE OP-
ERATOR.
The by-pass valve allows functioning with delivery closed only for short pe-
riods (max. 3 minutes).
To avoid damaging the pump, after use, make sure the pump is off.
In case of a power break, switch the pump off straight away.
Should any sealants be used on the suction and delivery circuit of the pump,
make sure that these products are not released inside the pump.
Foreign bodies in the suction and delivery circuit of the pump could cause
malfunctioning and breakage of the pump components.
BEFORE ANY OPERATION, ENSURE TO BE OUT OF POTENTIALLY EX-
PLOSIVE AREAS FOR SAFETY REASONS IT'S NOT ALLOWED TO DISAS-
SEMBLE THESE PARTS : (1) BOTTOM (2) MOTOR PIPE (3) PUMP BODY
FOR SAFETY REASONS IT IS FORBIDDEN TO REMOVE THE PARTS
"BOTTOM PLATE" (1), "MOTOR TUBE" (2), "PUMP BODY" (3) AND LE-
VER PIN (4).
EX50 - EX75 12V
31
31 /132