Piusi EX50 Manual Para El Uso Y El Mantenimiento página 21

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66
EN (Translation of the original language)
ZONE 22
Place where it is improbable that an explosive atmosphere, in the form of a cloud of
combustible powders in the air, occur during normal operation but which, if it does oc-
cur, only persists for a short time.
Note: This zone can comprise, among others, places near appliances, protections sys-
tems and components containing powder, out of which the powder can come out due to
leaks with the formation of powder deposits (e.g., milling salt, where the powder comes
out of the mills and deposits).
ZONE 1
ZONE
2
3.2
INTENDED USE
INTENDED
USE
FORBIDDEN
USE
PLANT OPERATION RESTRICTIONS IT IS FORBIDDEN:
1
2
3
4
5
6
7
3.3
HANDLING AND TRANSPORT
Due to the limited weight and dimensions of the pumps, special lifting equipment is not required to
handle them. The pumps are carefully packed before dispatch. Check the packing when receiving the
material and store in a dry place.
This manual belongs to PIUSI S.p.A. Whole or partial reproduction of this manual is forbidden.
PUMP FOR TRANFERRING FUEL SUITABLE FOR OPERATING IN ZONES
CLASSIFIED"1"AND "2", ACCORDING TO DIRECTIVE 99/92/CE
THE DETERMINATION OF THE AREAS (ZONES) IS TO BE CARRIED OUT
BY THE USER
Using the appliance for fluids other than those listed at paragraph "Fluids per-
mitted" and for uses other than those described at the item "authorised use"
is forbidden.
To use the appliance in a construction configuration other than that contem-
plated by the manufacturer
To use the appliance with fixed guards tampered with or removed.
To use the appliance in places where there is risk of explosion and/or fires clas-
sified in the following zones: 0; 20; 21; 22
To integrate other systems and/or equipment not considered by the manufac-
turer in the executive project.
To connect the appliance up to energy sources other than those contemplated
by the manufacturer
To use the commercial devices for purposes other than those indicated by the
manufacturer.
To use in case of lightnings
EX50 - EX75 12V
ZONE 0
ZONE 20
ZONE 21
21
21 /132
/124
loading

Productos relacionados para Piusi EX50

Este manual también es adecuado para:

Ex75