Installation, use and maintenance
WARNING
WARNING
WARNING
7
TECHNICAL DATA
7.1
PERFORMANCE SPECIFICATIONS
The performance diagram shows flow rate as a function of back pressure.
EX50
Functioning Point
A - (Maximum Flow
Rate)
B - (Base system)
C - (By-Pass)
EX75
Functioning Point
A - (Maximum Flow
Rate)
B - (Base system)
C - (By-Pass)
24 /132
The electrical connection between the plug and socket must be kept well
away from water.
THE PUMP IS EQUIPPED WITH CURRENT-SENSING PROTECTION. IF IT ACTIVATES TURN
OFF THE PUMP IMMEDIATELY.
THE PUMP IS EQUIPPED WITH PROTECTION AGAINST OVERHEATING AND OVER-
LOAD RISKS. SHOULD SUCH DEVICES ACTIVATE, THE PUMP SHUTS DOWN AUTO-
MATICALLY, BUT THE MASTER SWITCH IS NOT TURNED OFF. IT IS IMPORTANT TO
STOP THE PUMP USING ITS SWITCH. THE PUMP RESTARTS AFTER ITS NORMAL OP-
ERATING CONDITIONS HAVE BEEN RESTORED.
FAILURE TO OBSERVE THE ABOVE MENTIONED RULES CAN CAUSE SE-
RIOUS ACCIDENTS
SHOULD THE HEAT SENSOR ACTIVATE UNDER NORMAL USE CONDITIONS, PLEASE CON-
TACT THE TECHNICAL SUPPORT.
15
57 - 15
17
40 - 10,5
25
15
75 - 20
20
65 - 17
26
0,2 - 3
0,5 - 7
0
1,1 - 16
0,2 - 3
0,7 - 10
0
1,1 - 17.5
Typical delivery
configuration
•
•
Delivery Closed
Typical delivery
configuration
•
•
Delivery Closed
M0217E