Problem
No display on LCD (Screen is
blank).
"Cell On" indicator does not
come on.
If No Flow also....
If No Flow also....
"No Flow" indicator stays on
continuously.
|
Zodiac
Nature
2
Fusion soft
Installation and Operation Manual
®
®
Possible Cause
Clogged or dirty cell.
No Power to Unit.
Loose ribbon cable between front and back
PC board.
Incorrectly wired. Unit not wired for 240 VAC.
Loose or bad connection at white connector
between transformer and PC board.
Chlorine Production set to 00%.
Insufficient water flow. Cell is plugged with
debris, pump has lost prime.
Flow/temp/salinity sensor not plugged in.
Salt level below 2.0 gpl (2000 ppm).
Pump fails to provide sufficient water flow.
Improperly set valves or closed valves.
Clogged basket or dirty filter.
Obstruction in the Nature2 Fusion Soft cell.
Flow/temp/salinity sensor not installed
properly.
Flow/temp/salinity sensor not plugged in.
Flow/temp/salinity sensor elements covered
with PVC glue, taped over, or covered with
other debris.
Defective flow/temp/salinity sensor.
ENGLISH
Corrective Action
Remove cell for inspection. Clean
if necessary. See Section 6, User
Maintenance Instructions.
Check power. Turn on pump.
1. Defective automatic timer or pump
switch.
2. Loose connection at automatic timer or
pump switch.
Check that ribbon cable is fully inserted
into connector.
Check that unit is correctly wired for 240
VAC and connected to 240 VAC.
Check connector at white plug to insure
proper connection. If burnt connector
contact a qualified service representative.
Adjust CHLORINE PRODUCTION to
desired Percentage.
Remove obstruction and/or clean cell.
See Section 6.5, Electrolytic Cell Cleaning.
Prime pump if necessary.
Plug in flow/temp/salinity sensor. See
Section 3, Figure 11, Figure 12, and Figure
13.
Add salt as described in Section 4.6.3.
Check for correct operation of the pump.
Ensure there is no loss of pump prime or
clogged strainer baskets.
Check and correct all valve alignments.
Follow filter cleaning procedures.
Remove cell for inspection. Follow
cleaning procedures. See Section 6.5,
Electrolytic Cell Cleaning.
Ensure that the flow/temp/salinity sensor
is installed according to Section 3, Figure
10. If not, contact a qualified service
representative.
Plug flow/temp/salinity sensor into
connector on power center printed circuit
board. Turn power to unit off and back
on (Cycle Power). See wiring diagram
in Figure 11, Figure 12, and Figure 13.
See also, Section 6.6, Flow/Temp/Salinity
Sensor Cleaning, Step 4.
Remove and clean flow/temp/salinity
sensor and reinstall. See Section 3.11 and
Section 6.5.
Contact a qualified service representative.