Stabilizer (Cyanuric Acid). Test pool water stabilizer (cyanuric acid) level using a test kit or by having a water
sample tested by a qualified service representative. Maintain ideal range of 10 - 50 ppm. Follow your qualified
service representative's recommendations. Stabilizer is not necessary for indoor pool use.
5.
Calcium Hardness. Test pool water for calcium hardness level using test kit or by having a water sample tested
by a qualified service representative. If necessary, adjust according to your qualified service representative's
recommendations. APSP standard of 150 - 400 ppm is recommended.
Metals Test. It is recommended that the pool water be tested periodically for the presence of metals such as iron,
6.
and manganese. These metals should not be present in the pool water. If those metals are present, contact the
local qualified service representative.
6.4
Every Six (6) Months (Or once every pool season whichever is shorter)
6.4.1 Nature
Mineral Cartridge Replacement
2
The Nature
cartridge for the Nature
2
shorter length of time).
1.
Shut off the pool pump and filter.
2.
Close valves between filter and pool to prevent pool draining.
3.
Turn large collar counterclockwise to remove and lift off cap.
4.
Remove old cartridge and discard in household trash. Insert the new cartridge (see Section 4.3)
5.
Position cap flat on the vessel housing.
IMPORTANT
Make sure the o-ring is secure in the groove on the vessel top, not on the underside of the
cap. Turn large collar clockwise until it locks into place, do not over tighten.
6.
Open any valves that were closed to isolate the Nature
6.5
Electrolytic Cell Cleaning - As Needed
Depending upon water chemistry, occasional manual cell cleaning may be necessary.
1.
Switch off the filter pump and chlorinator, close necessary valves.
Always turn pump off prior to installing or removing any components from the pool's plumbing. Your pump/filter
system is operated under pressure and pressure must be released before you begin to avoid system damage,
serious personal injury, or death. Open the air relief valve on your pool filter to release the pressure in the system.
Be sure to follow the pool filter manufacturer's instructions to ensure this is done properly.
2.
Unplug the yellow connector from the vessel.
3.
Unscrew the electrolytic cell retaining ring and remove the electrolytic cell.
4.
Look down into the electrolytic cell to see if there is scale on the plates.
To avoid personal injury when working with pool chemicals, always wear rubber gloves and eye protection, cover
exposed skin, and work in a well ventilated area. Use caution when choosing a location to open and use chemicals
as they may damage any surface into which they come in contact. If any chemical gets on your skin, rinse the area
immediately with water. If any chemical gets on your clothing, immediately remove the piece of clothing and rinse
with water.
|
Zodiac