Page 18
ENGLISH
3.11 Connecting the Nature
ATTENTION INSTALLER: If the flow/temp/salinity sensor is not installed properly, it may allow the vessel to
operate without water flow. This would cause a buildup of flammable gases resulting in FIRE or EXPLOSION.
• Mount as shown in Figure 10. This will result in the most reliable operation.
• IMPORTANT! Anytime the flow/temp/salinity sensor is connected or disconnected and reconnected,
the AC power to the unit must be turned off and back on (Cycle Power). If power is not cycled, unreli-
able operation of the flow/temp/salinity sensor will result.
1.
Be sure pool pump is turned off.
2.
Install the flow/temp/salinity sensor into the vessel (see Figure 10).
3.
Install the strain relief provided with the vessel kit into the low voltage knock out at the power pack. Feed the
connector end of the flow/temp/salinity sensor cable through the DC cord strain relief fitting. Be certain the
connector is clean and dry, then plug the cable into the connector on the power center printed circuit board as
shown in Figure 11, Figure 12 and Figure 13. (Do not pull flow/temp/salinity sensor cable too tight, allow some
slack).
4.
Plug the DC cord into the cell stud terminals protruding from the cell top at the Nature
DC cord can be plugged into the cell in either direction.
5.
Connect the DC cord to the power center. Feed the DC cord through the same strain relief fitting as the flow/
temp/salinity sensor at the power pack. Plug the DC cord into the two (2) spade connectors of the wiring harness
located in the low voltage raceway of the control/power center, see Figure 11, Figure 12 and Figure 13. This
wiring harness establishes the connection between the cell and the power interface board.
To avoid risk of damage to the equipment and possible injury, it is important to make sure the DC cable connector is
fully seated on the cell electrolytic stud terminals.
Figure 10.
Vessel Installation and Flow/Temp/Salinity Sensor
Zodiac
Nature
2
Fusion soft
®
®
Fusion Soft Vessel and Flow/Temperature/Salinity Sensor
2
WARNING
CAUTION
|
Installation and Operation Manual
Sometimes
Salinity
Not Covered
Studs
Flow/Temp/Salinity Sensor Face must
be clean at all times for proper operation
Fusion Soft vessel. The
2
Temperature
Sensors