Section 5.
Operating Instructions
NOTE The user interface is located inside the control/power center. To access the control panel, open the door to the
control/power center. See Figure 19.
Figure 19.
User Interface
NOTE When a pool pump timer is used to limit chlorinator run time, the 24 hours will only count down when the
chlorinator is on.
Temperature
Press the POOL TEMP -BOOST- button D to check the pool water temperature. Temperature measurements can be
displayed in either Fahrenheit or Celsius. For more information, see Section 8, Temperature Conversion.
Operating User Interface Controls when AquaLink RS Control System is Online
Chlorine Production Rate Adjustment with AquaLink RS Online
The user interface can be used to adjust the output production rate (%) when the saltwater chlorinator system is controlled by
the AquaLink RS only when the AquaLink RS is placed into service mode. When the down arrow button A or the up arrow
button B is pressed, a JA in the display indicates that the AquaLink RS is controlling the entire system, including the output
production rates.
The AquaLink RS Control System must be set to Service Mode before you can change the chlorine production rate from the
control/power center user interface.
NOTE The Boost button at the user interface will start Boost cycle whether the AquaLink RS is online or offline.
AquaLink RS Control System
Press the Mode Select button to move the AquaLink RS from Auto Mode into Service Mode. The Service indicator light will
turn ON.
|
Zodiac
Nature
2
Fusion soft
Installation and Operation Manual
®
®
5.1
User Interface Controls
Chlorine Production Rate Adjustment
Pressing the down arrow button A or the up arrow button B will
change the CHLORINE PRODUCTION RATE in 5% increments.
Generally, adjustments to production should be made in 10%
increments.
In the PureLink
can be made from either the AquaLink® RS control panel or from the
power center user interface.
Salinity
Press the SALINITY button C to check the salinity of the water in
pool.
Boost
Press and hold the POOL TEMP -BOOST- button D for 10 seconds
to enter the Boost mode (Note 'bo' will flash intermittently). Boost
can be used to set chlorine production to maximum (100%) for 24
hours of operation. After 24 hours of chlorinator run time, chlorine
production will return to previous setting. To clear the Boost mode,
press and hold the POOL TEMP -BOOST- button D again for 10
seconds.
system, adjustments to the chlorine production rate