The screw which is closest to the head is
primarily for adjusting the upper end of the
scale range.
Each screw has a minor effect on the
adjusting range of the other screw.
To protect the mechanisms from dirt,
these two holes are plugged.
To adjust the wrench, you will need the
torque tester and an Allen key, size 2 mm.
Proceed as follows:
1. Remove both plugs using a sharp
implement. Retain the plugs.
2. To adjust the lower end of the scale,
insert the Allen key in the hole nearer
to the control knob. To adjust the
upper end of the scale, insert the
Allen key in the other hole.