Pause function
The Pause function allows temporary pausing of
the cooking process, allowing the users to
answer the door or the telephone without
worrying that the water is boiling over. This
function is also useful to clean the user interface
surface without changing the cooking set up.
To select this functio , the user should touch
"timer +/- keys" together.
If the "timer +/- keys" are touched for ½
seconds :
A beep sounds and the cooktop is stopped,
The heaters actual power setting is stored and
all the active heaters power is set to power level
0,
The heaters auto-swich off time is paused,
All the timers running count downs are paused,
All keys are locked except "timer +/- keys" and
"on/off key" (Timer keys can only be active if they
are used together to deactivate pause
function), timer displays nothing, and all the
heaters displays are getting on and puting out
"0", switching on segment by segment in left
direction, and after that switching off segment
by segment in right direction, continously.
The stop function will finish:
If the "timer +/- keys" (together) are touched for
more than ½ second a beep sounds and the
heaters actual power setting and timer
countdowns are restored, or if the cooktop is
stopped for more than 10 minutes the cooktop
is switched off automatically.
Overflow security
Something (an object or a liquid) is pressing any
key during more than 5s. 2 Short Beep + 1 Long
beep every 30s while the key is pressed. Cook-
top will turn Off.
blinking while the matter persist.
Timer
To activate timer, heater must be selected and
its power level must be greater than "0";
This symbol will maintain
Select the zone to be timed. Power level of the
zone greater than 0. Static
zone being timed . "0 0" in the digits reserved for
the timer.
1) With "+" or "-" keys, timer time can be chosen.
No Beeps at time change.
2) Pressing simultaneously timer key the timer is
cancelled (goes to 00).
3) If timer "+" or "-" keys is maintained pressed
during TBD time, there is quick setting.
4) When setting timer time, it is possible to go
from "00" to "99" with "-" key, and from "99" to
"00" with "+" key.
5) Maximum time 99 minutes.
6) When the time is elapsed and the hob is
beeping, press any key and the alarm and digit
sequence will end.
7) It is possible to adjust the timer time while the
timer is previously running.
8) Power of timed zone can be modified without
consequences on the timer programming.
9) Last minute will be displayed by seconds (For
Variants only visible if we enter the timer
programming while the last minute of the
countdown)
10) Pressing the Timer key without any selected
zone and when no zone is being timed, does
nothing.
11) Pressing the Timer key without any selected
zone and when many zones are being timed,
the time shown in time digits changes in a
rotatory way, and shows the time whose
power display has the decimal point ON.
12) Alternatively Power (5s) and (0,5s) is
displayed in the zone being timed.
Remaining time is displayed in the digits reserved
for the timer. If multiple zones are timed, the
smallest remaining time is displayed, and the
decimal point is displayed in the corresponding
zone.
Residual Heat Indicator (In radiant heaters->
calculated)
The same indicators can be used for "residual
heat" indication as well. A time table must be
defined on this purpose: Rest Heat time=f
(power level, working time).
GB 64