Electrical connections
WARNING! Danger of electric shock!
Improper installation of the device can result in injury!
Compare parameters of the local electricity network with the information on the
device's rating plate.
Only connect the device in the case of full compliance!
Before connecting the device to the electricity network ensure that the voltage and
frequency values given on the rating place match those of the existing electrical
installation.
Voltage tolerance is ± 10%.
The connection to the electricity network must conform to all international, domestic
and local regulations.
The device is equipped with a VDE 3 x 1.5 mm
The device must be connected to an equalizer (grounding).The connection clamp is
located at the rear of the device, on the right side under the label
The socket's electrical circuit must be secured to a minimum of 16A. Only connect
the device to a wall socket; do not use extension cords or power strips to avoid the
risk of overheating and fire.
Locate the device so that the plug is easily accessible for the device to be quickly
disconnected if the need arises.
Gas connection
The device has been produced and verified for use with the type of gas given on the
rating plate. Ensure before installation that the local gas source (type and pressure)
are compliant with the device's parameters.
When installing the device in public areas, be sure to follow all OHS rules, as well as
fire and other relevant safety regulations.
The connection is located at the rear of the device, either on the left or right side.
Metal hose connection
The gas supply installation can be completed using a suitable hose that meets all
domestic norms. When doing so, a certified cutoff valve must be installed in an
easily-accessible place between the gas installation and the device, so that the flow
of gas can be stopped at any moment.
The hose length can not exceed 2 meters.
- 40 -
2
cable with plug.
.