Technical Data - TECE TECEprofil WC-Modul Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
Public/semi-public buildings ― Flush programme „Interval"
EN
Looped series installation in a multi-toilet system
The TECEprofil toilet module with integrated hygiene flush is assigned as the
last consumer in the potable water installation so the total pipe contents up to
the riser can be exchanged on an automatic flush. The continuously adjustable
flush volume means you can also exchange larger pipe volumes, such as in a
public toilet with multiple consumers. Unnecessary pipe volumes should be
avoided here too. The „Interval" flush programme is optimum for use in public
and semi-public areas. This also allows easy avoidance of shorter usage inter-
ruptions.

9. Technical data

Max. Water pressure:
Minimum flow pressure:
Calculation flow:
Input voltage:
Power consumption:
Protection class:
Power consumption of a hygienic flushing unit for 10 minutes flushing time per
day (= 50 litres):
Valve position
open
closed
30
10 bar (1 MPa)
1 bar (0.1 MPa)
5 l/min per valve
12 V DC
max. 9 W
Standby 0.25 W
IP 67
Power consumption
9 W
0,25 W
1,5 Wh/day
547,5 Wh/year
6 Wh/day
2190 Wh/year
total
2737,5 Wh/year
Tabla de contenido
loading

Tabla de contenido